Answers are grounded in this paper and cite their sources.
Minority carrier lifetime changes in MOS diodes implanted with 200 keV Ar+ or 80 keV Si+ in the dose range 1011 to 1016 ions/cm2 are investigated and related to the implanted ions and the damage in the substrate. Lifetime degradation observed after Ar+ implantation varies with the dose. A factor of 105 is achieved by implanting a dose of 1015 Ar+/cm−2. Contrarily Si+ implantation does not affect the lifetime up to 1014 Si+/cm2. For a higher Si+ dose the lifetime is reduced by four orders of magnitude. Transmission electron microscopy studies reveal no defects for implants up to 1012 Ar+/cm2 and 1014 Si+/cm2. At higher argon dose bubble like defects are identified. For Ar+ and Si+ ion doses close to the amorphization dose stacking faults and dislocation loops are observed additionally.
No takes yet. Share an insight, caveat, or question.
Kappert et al. (1979) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: