Key result
Vein of Marshall cannulation success rates varied significantly by ostium clock location, ranging from 100% in the ≤3 o'clock group to 77.8% in the 5-6 o'clock group (p=0.032).
Why the study?
Vein of Marshall (VOM) ethanol infusion improves rhythm control in AF, but identification and cannulation of the VOM can be technically challenging.
Does angiographic morphology of the vein of Marshall predict the success and difficulty of its cannulation in patients with atrial fibrillation?
Observational (n=162)
Does angiographic morphology of the vein of Marshall predict the success and difficulty of its cannulation in patients with atrial fibrillation?
Angiographic morphologic features of the vein of Marshall, specifically the ostium clock location, can predict the difficulty and success rate of its cannulation during ethanol infusion procedures for atrial fibrillation.
Background The vein of Marshall (VOM) ethanol infusion improves rhythm control in atrial fibrillation (AF). The identification and cannulation of the VOM can be technically challenging. This study aimed to assess the angiographic morphology of the VOM and investigate its value in the VOM ethanol infusion. Methods Patients with AF (n = 162) scheduled for combined catheter ablation and VOM ethanol infusion were enrolled. The VOM morphologic features in the right anterior oblique (RAO), the left anterior oblique (LAO), and the LAO cranial views were analyzed. The impact of morphology on the identification and cannulation of the VOM was investigated. Results The VOM was identified in 159 (98.1 %) and cannulated in 150 (92.6 %) patients. The VOM identification rate in the RAO and LAO/LAO cranial view was 97.3 % and 89.3 %, respectively. Of 134 patients with VOM identification in the LAO/LAO cranial view, 104 (77.6 %) had a VOM ostium clock location (VOMo Clock ) of ≤3 and 3–4 o'clock. The VOM cannulation success rate in the ≤3, 3–4, 4–5, and 5–6 o'clock groups was 100 %, 92.6 %, 88.5 %, and 77.8 %, respectively (p = 0.032). The median (interquartile range) cannulation time in the four groups was 10.5 (6.3), 12.0 (9.0), 13.0 (23.0), and 34.0 (30.0) minutes, respectively (p < 0.001). The diameter of the coronary sinus ostium in the RAO view and the VOMo Clock were independent predictors for difficult cannulation. Conclusions The VOM morphologic features in different angiographic views provide valuable information which could facilitate the identification and cannulation of the VOM.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2023) conducted an observational in Atrial fibrillation (n=162). Angiographic assessment of vein of Marshall morphology was evaluated on Vein of Marshall cannulation success rate and cannulation time based on ostium clock location (p=0.032). Vein of Marshall cannulation success rates varied significantly by ostium clock location, ranging from 100% in the ≤3 o'clock group to 77.8% in the 5-6 o'clock group (p=0.032).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: