Why the study?
Does muscle near-infrared spectroscopy accurately reflect femoral venous oxygen saturation during steady-state exercise in normoxia and hypoxia in healthy subjects?
Does muscle near-infrared spectroscopy accurately reflect femoral venous oxygen saturation during steady-state exercise in normoxia and hypoxia in healthy subjects?
Muscle near-infrared spectroscopy parallels femoral venous oxygen saturation during steady-state exercise in hypoxia, but not in normoxia.
Answers are grounded in this paper and cite their sources.
NIRS should not be assumed to reflect venous saturation in normoxic exercise; leaves open its validity during hypoxia.
Near-infrared spectroscopy (NIRS) is a noninvasive way of measuring muscular oxygenation. We evaluated the relationship between NIRS signal [infrared muscle oxygen saturation (IR-SO2mus)] and the femoral venous oxygen saturation (SfvO2) during cycling exercise. Six healthy subjects performed a 30-min steady-state exercise at 80% maximal oxygen uptake in normoxia and hypoxia (inspired O2 fraction = 0.105). IR-So2mus was recorded continuously throughout the tests with the NIRS probe located on the vastus lateralis. During exercise, blood samples were withdrawn every 5 min from radial artery and femoral vein catheters. In normoxia, IR-So2mus initiated a transient nonsignificant decrease at 5 min, then returned to preexercise level, whereas SfvO2 showed a fast decrease, reaching 18% saturation at 10 min without further change. By contrast, in hypoxia, IR-SO2mus and SfvO2 demonstrated a parallel decrease then stabilized at 10 min. We conclude that IR-SO2mus appears to parallel SfvO2 when both the arterial and venous oxygen contents decrease during steady-state exercise in hypoxia, whereas IR-SO2mus does not follow SfvO2 change in normoxia.
No takes yet. Share an insight, caveat, or question.
Costes et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: