Answers are grounded in this paper and cite their sources.
The selectivity of chemical mechanical polishing (CMP) is successfully enhanced due to the modification of the film surface by ultra-high-dose ion implantation for the first time. The removal rate (RR) of CMP for SiO2 and Si3N4 films was changed by implanted ions. On the other hand, polycrystalline silicon (poly-Si) films had no change regardless of ion implantation. When C+ is implanted at 3×1016 ions/cm2 into SiO2, the RR decreases by about 40% compared with that without implantation. However, no significant change was observed after the implantation of C+ at 1×1016 ions/cm2 or Si+ to SiO2 and poly-Si films. New findings about CMP mechanism that are against Borst’s Langmuir-Hinshelwood model have been made when the film is modified by using high-dose implantation.
No takes yet. Share an insight, caveat, or question.
Yuan et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: