Answers are grounded in this paper and cite their sources.
A fast-acting relay is energized at frequencies in the range 0.005-500 c/s by an electronic square-wave generator. The relay has change-over contacts, independent of earth, which may be used to give exponential condenser discharges in a conventional capacitor/resistance circuit. The square-wave generator triggers a pulse unit giving a square-pulse with an adjustable time-delay. The pulse duration and delay time are both in the range 50 μsec.-50 msec. Independently adjustable pulses may be obtained from two such pulse units. Circuits for monitoring the output amplitude and mark/space ratio are given: alternative output stages for both constant-current and balanced pulses are discussed.
No takes yet. Share an insight, caveat, or question.
V. H. Attree (1950) studied this question.