Key result
Haemoglobin >10.9 g/dl is linked to ~10.5-fold higher odds of arterial stiffness in dialysis patients.
Why the study?
It remains unclear why the optimal haemoglobin target is lower in CKD patients than in non-CKD persons, potentially due to opposing effects on arterial stiffness and pressure pulsatility.
How do serum haemoglobin concentrations relate to arterial stiffness and pressure pulsatility in patients undergoing chronic dialysis?
Cross-Sectional (n=48)
No
How do serum haemoglobin concentrations relate to arterial stiffness and pressure pulsatility in patients undergoing chronic dialysis?
This study provides a hemodynamic mechanism for maintaining a haemoglobin target around 11 g/dl in dialysis patients, balancing the opposing risks of increased arterial stiffness at higher levels and elevated pressure pulsatility at lower levels.
Answers are grounded in this paper and cite their sources.
Hb targets near 11 g/dl in dialysis warrant caution; cross-sectional data leaves causal effects on stiffness and pulsatility open for trials.
INTRODUCTION: It remains unclear why the optimal haemoglobin target is lower in patients with chronic kidney disease (CKD) than in non-CKD persons. Arteriosclerosis and consequent impaired arterial function comprise a central cardiovascular risk mechanism in CKD. We hypothesized that the optimal haemoglobin target depends on its opposing effects on arterial stiffness and pressure pulsatility in CKD. METHODS: Arterial stiffness (aortic pulse wave velocity), wave reflection (augmentation index, reflected wave pressure and reflection magnitude), and pressure pulsatility (central systolic and pulse pressure, peripheral pulse pressure, pressure amplification and forward wave pressure) were assessed in 48 dialysis patients. RESULTS: In established confounder and diabetes adjusted linear regression models, haemoglobin levels were directly associated with arterial stiffness (partial R=0.366, p=0.03) and inversely with central systolic pressure (partial R=-0.344, p=0.04), central pulse pressure (partial R=-0.403, p=0.01), peripheral pulse pressure (partial R=-0.521, p=0.001) and forward wave pressure (partial R=-0.544, p=0.001). The presence of heart failure and use of angiotensin converting enzyme inhibitors or angiotensin receptor blockers and erythropoietin stimulating agents did not materially alter these relationships upon further adjustment for the respective characteristics in the models, and in sensitivity analyses. In receiver operator characteristic curve analysis, the optimal haemoglobin concentration cut-off values in predicting arterial stiffness and increased central pulse pressure were remarkably similar at 10.95 g/dl and 10.85 g/dl, respectively, and with clinically useful sensitivities, specificities and positive and negative predictive values. In logistic regression models, a haemoglobin value of >10.9 mg/dl was associated with both arterial stiffness (>10 m/sec; OR (95% CI) = 10.48 (1.57-70.08), p=0.02) and normal central pulse pressure (>50 mmHg; OR (95% CI) = 7.55 (1.58-36.03), p=0.01). CONCLUSION: This study suggests that the optimal haemoglobin target in dialysis patients is ~11g/dl and determined by its differential and contrasting effects on arterial stiffness and pressure pulsatility.
No takes yet. Share an insight, caveat, or question.
Hsu et al. (2020) conducted a cross-sectional in Chronic kidney disease undergoing thrice-weekly dialysis (n=48). Haemoglobin concentration >10.9 g/dl vs. Haemoglobin concentration <=10.9 g/dl was evaluated on Arterial stiffness (aortic pulse wave velocity >10 m/sec) (OR 10.48, 95% CI 1.57-70.08, p=0.02). Haemoglobin >10.9 g/dl was independently associated with both arterial stiffness and normal central pulse pressure in dialysis patients.
Synapse has enriched 10 related papers. Consider them for comparative context: