In this paper we present the experimental results for the mobility of ions in argon-carbon dioxide gaseous mixtures (Ar-CO 2 ) for pressures ranging from 6 to 10 Torr and for reduced electric fields in the 10 Td to 25 Td range, at room temperature.The time-of-arrival spectra of the several mixture ratios studied revealed that the relative abundance of the ions and their mobilities depend on the mixture ratio. For Ar concentrations below 80% only one peak was observed in the spectra which was attributed to CO 2 + , while for Ar concentrations above 80% a second peak appears at the left side of the main peak, which may be due to impurities, probably H 2 O + . In this work, the time-of-arrival spectra from which reduced mobilities were obtained for Ar concentrations of 20% ( K 0 = 1.141±0.004 cm 2 V −1 s −1 ), 50% ( K 0 = 1.385±0.009 cm 2 V −1 s −1 ), 85% ( K 0 = 1.690±0.022 cm 2 V −1 s −1 ) and 95% ( K 0 = 1.954±0.043 cm 2 V −1 s −1 ) are displayed as well as other reduced mobilities values obtained similarly. The ion mobility study was performed at reduced electric field values typically used in gaseous detectors.
No takes yet. Share an insight, caveat, or question.
Encarnação et al. (2015) studied this question.