Key result
Mitral bioprosthetic valve position, compared with aortic position, was not associated with a significant difference in stroke or systemic embolism.
Why the study?
The impact of valve position on thromboembolic and bleeding events in patients with AF and bioprosthetic valves was uncertain.
Does mitral valve bioprosthesis compared to aortic valve bioprosthesis alter the risk of thromboembolism and bleeding in patients with atrial fibrillation?
Observational (n=159)
Yes
Does mitral valve bioprosthesis compared to aortic valve bioprosthesis alter the risk of thromboembolism and bleeding in patients with atrial fibrillation?
In patients with AF and bioprosthetic valves, thromboembolic risk does not differ by valve position, though unadjusted bleeding risk is higher with mitral bioprostheses.
Answers are grounded in this paper and cite their sources.
Higher bleeding rates with mitral bioprostheses warrant caution in AF; observational data leaves open independent effect of valve position.
BACKGROUND: The impact of valve position on thromboembolic and bleeding events in patients with atrial fibrillation (AF) and bioprosthetic valves is uncertain. METHODS: We analyzed 159 patients with AF after surgical single-valve replacement from the BPV-AF registry (Retro) (UMIN000034198), which was a multicenter, retrospective, observational registry that enrolled 214 patients with AF and bioprosthetic valves to assess differences in bioprosthetic valve position. Baseline characteristics and clinical outcomes were compared on the basis of the position of aortic or mitral bioprosthetic valves. The primary efficacy endpoint was stroke or systemic embolism, and the primary safety endpoint was major bleeding. RESULTS: There were 85 patients (53.5%) in the aortic valve (AV) group and 74 patients (46.5%) in the mitral valve (MV) group. The MV group had a lower body weight and a higher prevalence of prior major bleeding compared with the AV group. Thromboembolic and bleeding risk scores and the administration of antithrombotic agents were not significantly different between the groups. The primary efficacy endpoint was not significantly different [AV group: 8.2%; 2.25/100 person-years (PY); MV group: 4.1%; 1.01/100 PY] (log-rank, p = 0.23). The primary safety endpoint was significantly higher in the MV group (17.6%; 4.54/100 PY) compared with the AV group (5.9%; 1.59/100 PY) (log-rank, p = 0.049). The adjusted hazard ratio of the primary safety endpoint in the MV group relative to the AV group was 2.71 (95% confidence interval 0.86-8.54, p = 0.09). CONCLUSIONS: In Japanese patients with AF and bioprosthetic valves, thromboembolic risk does not differ on the basis of valve position. Bleeding risk is higher in patients with MV bioprostheses, although valve position itself might not be an independent predictor for bleeding.
No takes yet. Share an insight, caveat, or question.
Obayashi et al. (2021) conducted an observational in atrial fibrillation and bioprosthetic valves (n=159). Mitral bioprosthetic valve position vs. Aortic bioprosthetic valve position was evaluated on stroke or systemic embolism (p=0.23). Mitral bioprosthetic valve position, compared with aortic position, was not associated with a significant difference in stroke or systemic embolism.
Synapse has enriched 10 related papers. Consider them for comparative context: