Key result
AI-guided dispersion ablation plus PVI increases 12-month freedom from persistent AF by ~18 percentage points.
Why the study?
Although PVI is the cornerstone ablation procedure for AF, the optimal ablation strategy for persistent and long-standing persistent AF remains elusive, with AI-guided targeting of spatio-temporal dispersion suggested as a tailored alternative.
Does AI-guided tailored ablation targeting spatio-temporal dispersion in addition to PVI improve freedom from AF in patients with drug-refractory persistent AF?
RCT (n=370)
Double-blind
Randomized (1:1)
Yes
Does AI-guided tailored ablation targeting spatio-temporal dispersion in addition to PVI improve freedom from AF in patients with drug-refractory persistent AF?
AI-guided ablation of spatio-temporal dispersion areas in addition to PVI is superior to PVI alone in eliminating AF at 1-year follow-up in patients with persistent AF.
Answers are grounded in this paper and cite their sources.
Supports AI-guided tailored ablation plus PVI for persistent AF; confirms RCT superiority of dispersion targeting over anatomical PVI.
Although pulmonary vein isolation (PVI) has become the cornerstone ablation procedure for atrial fibrillation (AF), the optimal ablation procedure for persistent and long-standing persistent AF remains elusive. Targeting spatio-temporal electrogram dispersion in a tailored procedure has been suggested as a potentially beneficial alternative to a conventional PVI-only procedure. In this multicenter, randomized, controlled, double-blind, superiority trial, patients with drug-refractory persistent AF were randomly assigned to a tailored ablation procedure targeting areas of spatio-temporal dispersion, as detected by an artificial intelligence (AI) algorithm, in addition to PVI (tailored arm, n = 187, 23% women) or to a conventional PVI-only procedure (anatomical arm, n = 183, 19% women). The primary efficacy endpoint was freedom from documented AF with or without antiarrhythmic drugs at 12 months after a single ablation procedure. Secondary endpoints included freedom from any atrial arrhythmic events, and the secondary composite safety endpoint consisted of death, cerebrovascular events, or treatment-related serious adverse events. One year post-procedure, the trial met its primary efficacy endpoint, which was achieved in 88% of patients in the tailored arm compared with 70% of patients in the anatomical arm (log-rank P < 0.0001 for superiority). However, no significant difference between arms was observed for the freedom from any atrial arrhythmia endpoint after one ablation. The safety endpoint did not differ between arms, with procedure and ablation times being twice as long in the tailored arm. These results show that AI-guided ablation of spatio-temporal dispersion areas in addition to PVI is superior to PVI alone in eliminating AF at 1-year follow-up in patients with persistent and long-standing persistent AF. Ablation of subsequent organized atrial tachycardias may be needed to maintain sinus rhythm long term. ClinicalTrials.gov identifier: NCT04702451 .
No takes yet. Share an insight, caveat, or question.
Deisenhofer et al. (2025) conducted an RCT in Drug-refractory persistent and long-standing persistent atrial fibrillation (n=370). AI-guided tailored ablation targeting spatio-temporal electrogram dispersion plus pulmonary vein isolation (PVI) vs. Conventional pulmonary vein isolation (PVI) alone was evaluated on Freedom from documented atrial fibrillation with or without antiarrhythmic drugs at 12 months after a single ablation procedure (p=<0.0001 for superiority). AI-guided spatio-temporal dispersion ablation plus PVI was superior to PVI alone for 12-month freedom from AF in persistent AF.
Synapse has enriched 10 related papers. Consider them for comparative context: