Key result
Voltage-guided tailored ablation linked to ~62% lower 1-year arrhythmia recurrence vs. PVI alone in persistent AF.
Why the study?
Despite advances in catheter ablation techniques, freedom from atrial arrhythmias after pulmonary vein isolation remains limited, particularly in patients with persistent or long-standing persistent AF.
Does a tailored catheter ablation approach guided by low-voltage areas improve 1-year freedom from atrial arrhythmia compared to pulmonary vein isolation alone in patients with persistent atrial fibrillation?
Observational (n=118)
No
Does a tailored catheter ablation approach guided by low-voltage areas improve 1-year freedom from atrial arrhythmia compared to pulmonary vein isolation alone in patients with persistent atrial fibrillation?
In patients with persistent atrial fibrillation, a tailored ablation strategy guided by low-voltage areas and incorporating vein of Marshall ethanol infusion was associated with significantly lower 1-year arrhythmia recurrence compared to pulmonary vein isolation alone.
May support tailored low-voltage ablation in persistent AF; hypothesis-generating and requires randomized confirmation.
Introduction Catheter ablation is the treatment of choice in symptomatic patients with atrial fibrillation (AF) who do not respond to antiarrhythmic drug therapy, with pulmonary vein isolation (PVI) serving as the cornerstone of AF ablation. Despite advances in ablation techniques, freedom from atrial arrhythmias remains limited, particularly in patients with persistent or long-standing persistent AF. Methods and purpose Prospective single-center, observational study of consecutive patients referred for catheter ablation for persistent AF ablation between August 2022 and August 2024. Patients were submitted to a tailored ablation guided by the presence of low-voltage areas (LVA). Procedural endpoints and 1-year outcomes were assessed and compared to those of a propensity score-matched (1:1 ratio) cohort of patients submitted to only PVI during the same period. All REDO procedures were excluded. The primary endpoint was defined as freedom from any atrial arrhythmia of at least 30 seconds duration, regardless of symptoms, after the 3-month blanking period. Results A total of 118 patients (71% male, mean age of 62±10years) fulfilled our inclusion criteria and were included in our study, corresponding 59 to the tailored approach group and 59 propensity score-matched patients in the control group. Mean LA volume index was 45.5±13 and mean left ventricular ejection fraction was 48.1±14.51%. In the tailored group, sixty percent of patients underwent vein of Marshall (VoM) ethanol infusion, which was followed by creation of a posterior mitral line; A roof line was created in 8% of patients, a posterior box in 73%, and an anterior mitral line in 27%. At 1-year follow-up, 26 patients had recurrences of sustained atrial arrhythmia: AF in 21 patients, atrial flutter in 3 patients and atrial tachycardia in the remaining 2 patients. Overall, single-procedure freedom from atrial arrhythmia after the 3-month blanking period was 78%. The risk of recurrence was significantly lower in the tailored approach group compared with the control group (13.5% vs. 30.5%, p=0.019). The use of VoM ethanol infusion and a tailored approach were associated with freedom from atrial recurrence during follow-up with a HR= 0.271(95% CI 0.081-0.904), p=0.013 and HR=0.382(0.165-0.886), p=0.020, respectively. Conclusion A tailored approach guided by the presence of LVA was associated with a higher arrhythmia-free survival at 1-year of follow-up compared with performing PVI alone and VoM ethanol infusion was associated with a reduced risk of AF recurrence.
No takes yet. Share an insight, caveat, or question.
Simoes et al. (2026) conducted an observational in Persistent atrial fibrillation (n=118). Tailored catheter ablation guided by low-voltage areas (LVA) vs. Pulmonary vein isolation (PVI) alone was evaluated on Freedom from any atrial arrhythmia of at least 30 seconds duration after the 3-month blanking period (reported as atrial arrhythmia recurrence rate) (HR 0.382, 95% CI 0.165-0.886, p=0.020). Tailored ablation guided by low-voltage areas lowered 1-year atrial arrhythmia recurrence vs PVI alone in persistent AF (13.5% vs 30.5%, p=0.019; HR 0.382, 95% CI 0.165-0.886, p=0.020).