RT-3DTEE can be critical in accurately diagnosing the mechanism of mechanical mitral valve obstruction when 2D imaging is limited, thereby guiding appropriate therapy.
Answers are grounded in this paper and cite their sources.
RT-3DTEE may clarify valve obstruction mechanism when 2D is limited; hypothesis-generating case report requiring prospective validation.
Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities.
No takes yet. Share an insight, caveat, or question.
Kannan et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: