Why the study?
Does direct transfemoral TAVI without balloon pre-dilatation improve procedural safety and efficiency compared to TAVI with balloon pre-dilatation in high-risk patients with severe aortic stenosis?
Does direct transfemoral TAVI without balloon pre-dilatation improve procedural safety and efficiency compared to TAVI with balloon pre-dilatation in high-risk patients with severe aortic stenosis?
Direct transfemoral TAVI without balloon pre-dilatation is feasible and safe, significantly reducing procedural time, radiation, and contrast use without increasing complications compared to standard pre-dilatation.
Answers are grounded in this paper and cite their sources.
Direct TAVI without pre-dilatation was associated with lower procedural burden and similar safety; leaves open need for randomized confirmation before practice change.
OBJECTIVES: To evaluate the feasibility and safety of direct transcatheter aortic valve implantation (TAVI) by the transfemoral approach without balloon pre-dilatation using the Edwards SapienXT valve. BACKGROUND: TAVI is established in selected high-risk patients with severe aortic stenosis. Balloon aortic valvuloplasty (BAV) is recommended prior to valve implantation, but may contribute to procedural risk. It is unknown whether this is necessary for successful passage and deployment of the device. METHODS: 81 patients (mean age 84 [95%CI:82-85.8], 62% male, median EuroScore 22.8% [95%CI:20.5-27]) undergoing transfemoral TAVI (35 by direct implantation [direct group]; 46 with balloon pre-dilatation [balloon group]) between 2010 and 2013 were analyzed for efficacy and safety endpoints. RESULTS: Procedural success was 100%. Pre and post-procedural peak gradients in the direct group were 66mmHg (95%CI:59-72.8) and 14mmHg (95%CI:12-17.8)(P < 0.0001) compared to 76.5mmHg (95%CI:73.7-94.0) and 17mmHg (95%CI:16-19)(P < 0.0001) in the balloon group. Post-dilatation was performed in 4/35(11.4%) of the direct group and 3/46(6.5%) of the balloon group (P = 0.83). Post procedure moderate AR was present in 1/35(2.9%) in the direct group and none in the balloon group. In-hospital mortality (2.9% direct vs. 0% balloon group), stroke (2.9% vs. 4.4%), tamponade (2.9% vs. 2.2%), major vascular complications (2.9% vs. 8.7%) and new permanent pacing (2.2% vs. 0) were similar. Pacing time, inflations, radiation dose and contrast use were all significantly lower in the direct group. CONCLUSIONS: Direct implantation of the Edwards SapienXT valve during TAVI by the transfemoral route appears safe, efficacious and feasible in those without extreme calcification.
No takes yet. Share an insight, caveat, or question.
Bandali et al. (2016) studied this question.