Why the study?
What are the poorly recognized echocardiographic findings in patients with pericardial effusion?
What are the poorly recognized echocardiographic findings in patients with pericardial effusion?
Pericardial effusion can cause misleading echocardiographic findings such as apparent valve prolapse and systolic anterior motion, which resolve after fluid drainage.
Answers are grounded in this paper and cite their sources.
Pericardial effusion may produce misleading echocardiographic valve findings that resolve with drainage; case reports leave open their frequency and significance.
New, poorly recognized echocardiographic findings were recorded in six patients with pericardial effusion. These findings were apparent prolapse of mitral and tricuspid valves, apparent systolic anterior motion of mitral valve, and midsystolic notching of pulmonic valve. Beat-to-beat variation of the dimensions of right and left ventricle and in the diastolic opening amplitude of the anterior mitral valve were present in cardiac tamponade. Substantial decrease or resolution of effusion resulted in disappearance of the observed abnormalities. Serial echographic studies before and after fluid resolution may prevent misleading echographic and clinical diagnoses.
No takes yet. Share an insight, caveat, or question.
Samuel Zoneraich (1976) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: