Key result
Angiographic coronary atherosclerosis in geriatric patients was significantly associated with reduced oscillatory arterial compliance (C2) compared to patients with normal coronary angiograms.
Why the study?
Is oscillatory arterial compliance (C2) associated with angiographic coronary atherosclerosis in elderly patients?
Observational (n=105)
Is oscillatory arterial compliance (C2) associated with angiographic coronary atherosclerosis in elderly patients?
Oscillatory arterial compliance (C2) is significantly reduced in elderly patients with angiographic coronary atherosclerosis and correlates with disease severity, suggesting its potential utility in early diagnosis.
Answers are grounded in this paper and cite their sources.
Reduced C2 may mark atherosclerosis in geriatrics; hypothesis-generating and should not change practice pending validation.
This study investigated the value of arterial elasticity measurement in the early diagnosis of angiographic coronary artery atherosclerosis in 105 consecutive elderly patients. They were divided into two groups according to the results of selective coronary angiography: 55 with coronary atherosclerosis and 50 with a normal coronary angiogram. The Gensini score of the coronary artery was acquired and capacitive arterial compliance (C1) and oscillatory arterial compliance (C2) were measured. An independent-sample t-test was used to evaluate the difference in C1 and C2 between the two groups. Bivariate analyses were performed to study the association between the Gensini score and C1 and C2. A significant difference between the two groups in C2 was found and the Gensini score of the coronary artery was significantly correlated with C2. Identification of early coronary atherosclerosis in geriatrics may be aided by the prognostic value of C2.
No takes yet. Share an insight, caveat, or question.
You et al. (2009) conducted an observational in Coronary artery atherosclerosis (n=105). Angiographic coronary atherosclerosis vs. Normal coronary angiogram was evaluated on Capacitive arterial compliance (C1) and oscillatory arterial compliance (C2). Angiographic coronary atherosclerosis in geriatric patients was significantly associated with reduced oscillatory arterial compliance (C2) compared to patients with normal coronary angiograms.
Synapse has enriched 10 related papers. Consider them for comparative context: