Key result
Exercise scintigraphy reveals reversible perfusion defects in ~64% of exercise-induced LBBB patients despite normal coronaries.
Why the study?
To assess the diagnostic value of thallium-201 myocardial imaging for coronary artery disease and evaluate whether the pathogenesis of exercise-induced rate-dependent left bundle branch block is ischaemic.
What is the diagnostic value of exercise thallium-201 myocardial scintigraphy in patients with exercise-induced left bundle branch block?
Observational (n=33)
What is the diagnostic value of exercise thallium-201 myocardial scintigraphy in patients with exercise-induced left bundle branch block?
Exercise-induced LBBB frequently causes reversible septal perfusion defects on thallium-201 scintigraphy in the absence of obstructive coronary artery disease, which may lead to false-positive diagnoses of ischemia.
Answers are grounded in this paper and cite their sources.
May support CAD evaluation in exercise-induced LBBB; leaves open diagnostic accuracy and need for prospective validation.
Myocardial perfusion scintigraphy with thallium-201 was performed in 33 subjects (mean age 45 years, range 28-61) with exercise-induced, rate-dependent left bundle branch block (LBBB) in order to assess both the value of Thallium-201 myocardial imaging for the diagnosis of coronary artery disease (CAD) and the pathogenesis (ischaemic or not) of the conduction defect. Of the 33 patients evaluated, 16 had chest pain suggestive of CAD and 17 were asymptomatic. None had a history of prior myocardial infarction or clinical and echocardiographic signs of heart disease. LBBB appeared at a heart rate ranging from 70 to 160 b.min-1. Eighteen patients showed repolarization abnormalities (ST segment depression with deep inverted T waves) compatible with ischaemia, after QRS normalization. Thallium-201 myocardial uptake was normal in 12 subjects; in the remaining 21, reversible Thallium-201 defects were demonstrated in the septum (18 patients), septum and apex (2), and septum and infero-apical wall (1). No patient had irreversible defects and all had normal coronary angiography, with negative ergonovine tests for coronary artery spasm. The patients were followed up for a mean of 43 months (range 16-80). One patient died from sudden death, but no cardiac event occurred in the other patients. In conclusion, exercise Thallium-201 myocardial scintigraphy showed a high prevalence (64%) of reversible perfusion defects in a group of patients with exercise-induced LBBB without any evidence of CAD at angiography or coronary spasm at ergonovine test. Moreover, follow-up showed a relatively low rate of major cardiac events.
No takes yet. Share an insight, caveat, or question.
Canna et al. (1992) conducted an observational in Exercise-induced left bundle branch block (n=33). Thallium-201 myocardial perfusion scintigraphy was evaluated on Reversible Thallium-201 perfusion defects. Exercise Thallium-201 myocardial scintigraphy revealed a 64% prevalence of reversible perfusion defects in patients with exercise-induced LBBB, despite normal coronary angiography.
Synapse has enriched 10 related papers. Consider them for comparative context: