The clinical effects and optical coherence tomography findings of using the Bioengineered Combo Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent in patients with chronic total occlusion were not established.
Does the Bioengineered Combo Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent improve clinical and OCT outcomes in patients with chronic total occlusion?
Does the Bioengineered Combo Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent improve clinical and OCT outcomes in patients with chronic total occlusion?
The use of the Combo Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent for CTO recanalization is associated with a high rate of angiographic restenosis (40%) driven by neointima formation, despite good initial implantation.
Answers are grounded in this paper and cite their sources.
Small retrospective series supports Combo DTS feasibility in CTO; hypothesis-generating and requires randomized trials before practice change.
We sought to determine the effects of the use of a Bioengineered Combo Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent (Combo® DTS) in patients with chronic total occlusion (CTO) by evaluating clinical outcomes and by performing an optical coherence tomography (OCT) analysis. We retrospectively analyzed data from 39 patients who had successfully undergone OCT-guided revascularization of a CTO being treated with a Combo® DTS. Clinical assessment, angiography (with quantitative coronary angiography analysis) and OCT examination were performed at baseline and at follow-up. The median follow-up period was 189 days, ranging from 157 to 615 days. At follow-up, revascularization was required due to angiographic restenosis in 40% (14 of 35) of patients. OCT analysis detected neointima proliferation in 23 (76.6%) patients. Neointima formation was often associated with microvessels in 18 patients (60%). Neoatheroslcerosis was observed in 2 (6.6%) patients. Malapposition was found in 4 patients (13.3%), and stent fractures were found in 11 patients (36.6%). Rate of strut coverage was 96.3% at follow-up. In conclusion, the implantation of a Combo® DTS after successful CTO recanalization was associated with a restenosis rate of 40% despite good stent implantation at baseline, proven by OCT. Neointima formation was found as a main contributor to restenosis. Nevertheless, we observed a low rate of major cardiovascular events in our follow-up.
No takes yet. Share an insight, caveat, or question.
Blessing et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: