Answers are grounded in this paper and cite their sources.
The present work focuses on the question of localizing single object by hard x-ray phase contrast projection imaging. The authors present a setup where an x-ray channel waveguide defines a “quasi-point source” used to illuminate and image an object in a highly coherent cone beam. Knife edge fluorescence scans revealed a beam diameter of 75nm at a distance of 30μm behind the guide. The recorded image corresponds to an in-line hologram of the object which can be reconstructed numerically. Object translations and associated shifts in the hologram allow for the 10nm localization accuracy.
No takes yet. Share an insight, caveat, or question.
Ollinger et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: