Key result
Patients with COPD and lung hyperinflation had significantly impaired spontaneous mean baroreceptor reflex sensitivity during rest compared to healthy controls (5.6 vs. 12.0 ms/mmHg).
Why the study?
Patients with COPD are at increased risk for cardiovascular disease, motivating an investigation into the relationship between pulmonary hyperinflation and baroreceptor reflex sensitivity.
Does lung hyperinflation in COPD impair baroreceptor reflex sensitivity compared to healthy controls?
Case-Control (n=45)
No
Does lung hyperinflation in COPD impair baroreceptor reflex sensitivity compared to healthy controls?
Patients with severe COPD and lung hyperinflation exhibit significantly impaired spontaneous baroreceptor reflex sensitivity and reduced stroke volume compared to healthy controls, suggesting a mechanism for increased cardiovascular risk.
Background and Objectives: Patients with chronic obstructive pulmonary disease (COPD) are at increased risk for cardiovascular disease. This study aimed to investigate the relationship between pulmonary hyperinflation and baroreceptor reflex sensitivity (BRS), a surrogate for cardiovascular risk. Methods: 33 patients with COPD, free from clinical cardiovascular disease, and 12 healthy controls were studied. Participants underwent pulmonary function and non-invasive hemodynamic measurements. BRS was evaluated using the sequence method during resting conditions and mental arithmetic stress testing. Results: Patients with COPD had evidence of airflow obstruction [forced expiratory volume in 1 s predicted (FEV1%) 26.5 (23.3–29.1) vs. 91.5 (82.8–100.8); P < 0.001; geometric means (GM) with 95% confidence interval (CI)] and lung hyperinflation [residual volume/total lung capacity (RV/TLC) 67.7 (64.3–71.3) vs. 41.0 (38.8–44.3); P < 0.001; GM with 95% CI] compared to controls. Spontaneous mean BRS (BRSmean) was significantly lower in COPD, both during rest [5.6 (4.2–6.9) vs. 12.0 (9.1–17.6); P = 0.003; GM with 95% CI] and stress testing [4.4 (3.7–5.3) vs. 9.6 (7.7–12.2); P < 0.001; GM with 95% CI]. Stroke volume (SV) was significantly lower in the patient group [−21.0 ml (−29.4 to −12.6); P < 0.001; difference of the means with 95% CI]. RV/TLC was found to be a predictor of BRS and SV (P < 0.05 for both), independent of resting heart rate. Conclusion: We herewith provide evidence of impaired BRS in patients with COPD. Hyperinflation may influence BRS through alteration of mechanosensitive vagal nerve activity.
No takes yet. Share an insight, caveat, or question.
A 2022 study conducted a case-control in Chronic obstructive pulmonary disease (COPD) (n=45). COPD with lung hyperinflation vs. Healthy controls was evaluated on Spontaneous mean baroreceptor reflex sensitivity (BRSmean) during rest (Ratio of geometric means 0.5, 95% CI 0.3-0.8, p=0.003). Patients with COPD and lung hyperinflation had significantly impaired spontaneous mean baroreceptor reflex sensitivity during rest compared to healthy controls (5.6 vs. 12.0 ms/mmHg).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: