Key result
Advanced ECG demonstrated high diagnostic accuracy for HFrEF, and AI-derived echocardiography measurements correlated well with manual assessments.
Why the study?
Multiomics delivers more biological insight than targeted investigations, prompting its application alongside machine learning, advanced ECG, and echocardiography artificial intelligence to evaluate patients with HFrEF.
Does machine learning applied to advanced ECG and echocardiography accurately diagnose and assess HFrEF?
Observational (n=66)
Does machine learning applied to advanced ECG and echocardiography accurately diagnose and assess HFrEF?
Machine learning applied to advanced ECG and echocardiography demonstrates high diagnostic accuracy for HFrEF, comparable to standard biomarkers like NT-proBNP.
Answers are grounded in this paper and cite their sources.
Multiomics with ML on AECG and Echo AI may refine HFrEF prognostication; hypothesis-generating and requires prospective validation before clinical use.
Aim: Multiomics delivers more biological insight than targeted investigations. We applied multiomics to patients with heart failure (HF) and reduced ejection fraction (HFrEF), with machine learning applied to advanced ECG (AECG) and echocardiography artificial intelligence (Echo AI). Patients & methods: In total, 46 patients with HFrEF and 20 controls underwent metabolomic profiling, including liquid/gas chromatography–mass spectrometry and solid-phase microextraction volatilomics in plasma and urine. HFrEF was defined using left ventricular (LV) global longitudinal strain, EF and N-terminal pro hormone BNP. AECG and Echo AI were performed over 5 min, with a subset of patients undergoing a virtual reality mental stress test. Results: A-ECG had similar diagnostic accuracy as N-terminal pro hormone BNP for HFrEF (area under the curve = 0.95, 95% CI: 0.85–0.99), and correlated with global longitudinal strain (r = -0.77, p < 0.0001), while Echo AI-generated measurements correlated well with manually measured LV end diastolic volume r = 0.77, LV end systolic volume r = 0.8, LVEF r = 0.71, indexed left atrium volume r = 0.71 and indexed LV mass r = 0.6, p < 0.005. AI-LVEF and other HFrEF biomarkers had a similar discrimination for HFrEF (area under the curve AI-LVEF = 0.88; 95% CI: -0.03 to 0.15; p = 0.19). Virtual reality mental stress test elicited arrhythmic biomarkers on AECG and indicated blunted autonomic responsiveness (alpha 2 of RR interval variability, p = 1 × 10-4) in HFrEF. Conclusion: Multiomics-related machine learning shows promise for the assessment of HF.
No takes yet. Share an insight, caveat, or question.
Gladding et al. (2021) conducted an observational in Heart failure with reduced ejection fraction (HFrEF) (n=66). Advanced ECG and echocardiography AI vs. Standard biomarkers and manual measurements was evaluated on Diagnostic accuracy for HFrEF (AUC 0.95, 95% CI 0.85-0.99). Advanced ECG demonstrated high diagnostic accuracy for HFrEF, and AI-derived echocardiography measurements correlated well with manual assessments.