Why the study?
Does digitalization with ouabain alter the diastolic threshold energy for repetitive ventricular response to electrical stimulation in an animal model?
Does digitalization with ouabain alter the diastolic threshold energy for repetitive ventricular response to electrical stimulation in an animal model?
Digitalization with ouabain profoundly reduces the threshold for repetitive ventricular responses to electrical stimulation, predisposing to ventricular tachycardia as toxicity approaches.
Answers are grounded in this paper and cite their sources.
May heighten arrhythmia risk during ouabain digitalization in animals; leaves open translation to human digitalis toxicity.
In the nondigitalized animal, a unipolar stimulus to the endocardium or myocardium discharged during diastole resulted in a single response unless energies greater than 5 J were used. During digitalization employing ouabain, the diastolic threshold energy for a repetitive ventricula response (RVR) was reduced by 6 orders of magnitude. RVR was first noted after 70% of the toxic dose of ouabain had been given and consisted of 2 ventricular ectopic beats. With advancing degrees of digitalization, a single stimulus evoked paroxysms of ventricular tachycardia. The most sensitive part of the cardiac cycle followed immediately after inscription of the T wave. As toxicity was approached, the zone of lowered threshold extended throughout most of the diastolic interval.
No takes yet. Share an insight, caveat, or question.
Lown et al. (1967) studied this question.