This is the authors' abstract. We don't add key points for this paper.
High-precision miniaturized micromechanical accelerometers are used extensively in the civilian and military fields. A novel self-test-on-chip method and time-multiplexing feedback method for capacitive accelerometers were proposed in this work. The self-test-on-chip circuit can simulate an acceleration signal to test the harmonic distortion without a high-precision shaker table. Using digital timing control, the time-multiplexing feedback can reduce the coupling between the feedback signal and the detection signal. In addition, a low-noise charge sensing and sigma-delta modulator were designed for a high-precision digital output. The interfaced circuit with fully differential topology was fabricated in a0.35 μ mstandard complementary metal-oxide semiconductor (CMOS) process. The integrated accelerometers can achieve a power consumption of 7 mW from a 5 V supply at a sampling frequency of 256 kHz, a noise floor of −140 dBV below 400 Hz. The equivalent input noise voltage density is 250nV/Hz, corresponding to a reference voltage of 2.5V. It can achieve an equivalent noise acceleration of0.14 μ gHz and a bias instability of9 μ gat a bandwidth of 400 Hz, a nonlinearity of 0.13% within ±1 g.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: