The constant-current (CC) method uses a current criterion to determine the threshold voltage (VTH) of metal-oxide-semiconductor (MOS) field-effect transistors. We show that using the same current criterion in both saturation and linear modes leads to inconsistent results and incorrect interpretation of effects, such as drain-induced barrier lowering in advanced CMOS halo-implanted devices. The generalized adjusted CC method is based on the theory of the charge-based MOS transistor model. It introduces an adjusted current criterion, depending onVDS, allowing to coherently determineVTHfor the entire range ofVDSfrom linear operation to saturation. The method uses commonly availableIDversusVGdata with focus on moderate inversion. The method is validated with respect to the ideal surface potential model, and its suitability is demonstrated with technology-computer-aided-design data from a 65-nm CMOS technology and measured data from a 90-nm CMOS technology. Comparison with other widely used threshold voltage extraction methods is provided.
No takes yet. Share an insight, caveat, or question.
Bazigos et al. (2011) studied this question.