A very small value of inter-electrode capacitance is a main factor limiting image spatial resolution of electrical capacitance tomography. The front-end sensing circuit of multichannel capacitance tomography system EVT4 was designed for measurement of extremely small capacitance values in the range from 1 fF to several pF. The capacitance value is determined by charging it using a single high voltage pulse and integrating a charging current. The idea of gain adjustment in the front-end amplifier of a capacitance measurement circuit is presented. The switchable feedback loop of the inverting preamplifier-a first stage of the sensing circuit-enables gain adjustment in a wide range. The measurements using a cylindrical 2-D capacitance sensor were performed without and with gain adjustment. The obtained results showed improvement of signal-to-noise ratio for the pairs of opposite electrodes from about 22 to 30 dB.
No takes yet. Share an insight, caveat, or question.
Kryszyn et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: