Key result
A novel semiquantitative scintigraphic method demonstrated significantly higher perfusion counts in the ischemic left arm compared to the resting right arm (22,203.3 vs 9,980.9, p<0.001), successfully imaging flow-mediated vasodilation.
Why the study?
Does a semiquantitative scintigraphic method using 99mTc-MIBI accurately measure endothelium-dependent vasodilation in the forearm of patients with cardiovascular risk factors?
Observational (n=118)
No
Does a semiquantitative scintigraphic method using 99mTc-MIBI accurately measure endothelium-dependent vasodilation in the forearm of patients with cardiovascular risk factors?
A novel semiquantitative scintigraphic method using 99mTc-MIBI can non-invasively evaluate endothelium-dependent vasodilation in the forearm, demonstrating reduced perfusion ratios in patients with hypertension and hypercholesterolemia.
May enable non-invasive scintigraphic FMD assessment; leaves open validation and outcome correlation in larger cohorts.
BACKGROUND: The diagnosis of endothelial dysfunction has been gaining clinical importance, but although endothelial function testing is available in the research setting, no technique yet exists that is simple, safe, reproducible and easily performed as a clinical screening method. The aim of this study was to design a new, scintigraphic method of imaging the flow-mediated dilation in the forearm, which represents the functional characteristic of endothelial dysfunction. METHODS AND RESULTS: The study group comprised 118 subjects in whom left forearm ischemia was induced by inflating a sphygmomanometer cuff to supra systolic pressure for 4.5 min. Later, dynamic acquisition (2 s frame/min) was initiated after the injection of technetium-99m methoxy-isobutyl isonitril into the dorsal pedal veins. Equivalent regions of interest were drawn on both arms to detect total activity counts during 1 min and the perfusion ratios (left arm/right arm) were calculated. The left arm counts (22,203.3+/-12,372.7) were significantly higher than the right arm counts (9,980.9+/-5,931.9) (p<0.001). A significant decrease in perfusion ratios was noted in the hypertension and hypercholesterolemia groups. An increase in the number of risk factors caused an insignificant decrease in perfusion ratio (p=0.346). CONCLUSION: Non-invasive evaluation of endothelium-dependent vasodilation by semiquantitative scintigraphic method using radioactive perfusion tracer provided promising results.
No takes yet. Share an insight, caveat, or question.
Karaçalıoğlu et al. (2006) conducted an observational in Risk factors for coronary artery disease (n=118). Forearm ischemia induced by sphygmomanometer cuff vs. Right arm (resting/no ischemia) was evaluated on Total activity counts during 1 minute (perfusion) (p=<0.001). A novel semiquantitative scintigraphic method demonstrated significantly higher perfusion counts in the ischemic left arm compared to the resting right arm (22,203.3 vs 9,980.9, p<0.001), successfully imaging flow-mediated vasodilation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: