Key result
Pregnancy with an existing ICD shows zero device complications or shocks despite frequent medication adjustments.
Why the study?
There are few studies investigating maternal and fetal outcomes in pregnant patients with an implantable cardioverter-defibrillator (ICD).
What are the maternal and fetal outcomes and safety profile in pregnant women with an implantable cardioverter-defibrillator?
Observational (n=6)
No
What are the maternal and fetal outcomes and safety profile in pregnant women with an implantable cardioverter-defibrillator?
Answers are grounded in this paper and cite their sources.
Pregnancy in women with an ICD does not appear to increase the risk of device-related complications, but requires careful monitoring for arrhythmias and cardiac function, particularly in the third trimester and postpartum period.
Background: There are few studies of pregnancy and delivery in patients with an implantable cardioverter-defibrillator (ICD). The purpose of this study was to investigate maternal and fetal outcome in these patients. Methods and Results: Six pregnant women with an ICD were retrospectively reviewed. All women underwent implantation of an ICD before pregnancy and delivered at the National Cerebral and Cardiovascular Center. The mean age at pregnancy and the mean follow-up period after ICD implantation were 28±3 years old and 5±3 years, respectively. There was no device-related complication during pregnancy. In 4 women, the number of tachyarrhythmias such as non-sustained ventricular tachycardia increased after the end of the second trimester of pregnancy and anti-arrhythmic medications were gradually increased. No patient received discharges or shocks from the ICD during pregnancy, however, and only one required anti-tachycardia pacing at 27 weeks’ gestation. Mean gestational age at delivery was 37±2 weeks and all deliveries were by cesarean section, including 5 as emergency deliveries due to a fetal indication. After delivery, 2 mothers had reduced cardiac function and 1 received an ICD shock for the first time. Conclusions: Pregnancy did not increase the risk of an ICD-related complication under appropriate management. Additional caution might be required in the postpartum period as well as during pregnancy and labor. (Circ J 2013; 77: 1166–1170)
No takes yet. Share an insight, caveat, or question.
Miyoshi et al. (2013) conducted an observational in Pregnancy with an implantable cardioverter-defibrillator (ICD) (n=6). Pregnancy with an implantable cardioverter-defibrillator was evaluated on Device-related complications during pregnancy. Among 6 pregnant women with an implantable cardioverter-defibrillator, there were zero device-related complications or shocks during pregnancy, though 4 patients required increased anti-arrhythmic medications.
Synapse has enriched 10 related papers. Consider them for comparative context: