Key result
Umbilical cord hs-cTnT predicts neonatal respiratory failure with ~0.85 AUC.
Why the study?
Data on umbilical cord and postnatal physiological limits of high sensitivity cardiac troponin T (hs cTnT) in newborns are scarce.
What are the normal values of hs cTnT in healthy newborns, and what is its clinical significance in neonatal respiratory failure?
Cross-Sectional (n=206)
What are the normal values of hs cTnT in healthy newborns, and what is its clinical significance in neonatal respiratory failure?
Effect estimate: AUC 0.848 (95% CI 0.79-0.90)
Provides normative hs-cTnT ranges in newborns; leaves open its role in neonatal respiratory failure.
Objective: Data on the umbilical cord and postnatal physiological limits of the high sensitivity cardiac troponin T (hs cTnT) in newborns are scarce.This study aims to determine the normal values and upper limits of hs cTnT in healthy newborns.In addition, its clinical significance and usability in neonatal respiratory failure were analyzed. Method:In this non-invasive and retrospective, cross-sectional study, 113 healthy newborns and 93 newborns with non-cardiac respiratory failure, born between July 2018 and January 2020, were evaluated.Hs cTnT was measured in the umbilical cord and 24-96 h after birth in infants.Results: In the healthy group, the median umbilical cord hs cTnT was 38 (17-156) ng/L and 99 th percentile hs cTnT was 122 ng/L, and in the respiratory failure group, the median umbilical cord hs cTnT was 72 (27-326) ng/L.Postnatal day 2-4 median hs cTnT was 75 (10-194) ng/L and 99 th percentile value was 194 ng/L in the healthy group, and the median hs cTnT was 145 (41-409) ng/L in the respiratory failure group.The calculated area under the ROC curve for umbilical cord hs cTnT was 0.848 [cut-off 64; 95% confidence interval (CI); 0.79-0.90:sensitivity 62.4% specificity 93.7%], suggesting that umbilical cord hs cTnT is a sensitive marker for the prediction of neonatal respiratory failure.The calculated area under the ROC curve for control hs cTnT was 0.851 (cut-off 121.5; 95% CI; 0.79-0.90;sensitivity 71% specificity 86.8%), suggesting that control hs cTnT is a sensitive marker for the prediction of neonatal respiratory failure. Conclusion:The results show that the reference range of umbilical cord and postnatal hs cTnT in healthy newborns is higher than that in adults.Both hs cTnT values were higher in the neonatal respiratory failure group than those in the healthy group.
No takes yet. Share an insight, caveat, or question.
Tüfekçi et al. (2021) conducted a cross-sectional in Neonatal respiratory failure (n=206). High sensitivity cardiac troponin T (hs cTnT) vs. Healthy newborns was evaluated on Prediction of neonatal respiratory failure using umbilical cord hs cTnT (AUC 0.848, 95% CI 0.79-0.90). Umbilical cord high sensitivity cardiac troponin T is a sensitive marker for predicting neonatal respiratory failure, demonstrating an AUC of 0.848 (95% CI 0.79-0.90).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: