Why the study?
Does an increased percentage of VV' alternans triplets on near-field ICD electrograms predict nonarrhythmic death versus appropriate ICD shock in patients with structural heart disease?
Does an increased percentage of VV' alternans triplets on near-field ICD electrograms predict nonarrhythmic death versus appropriate ICD shock in patients with structural heart disease?
In ICD patients with structural heart disease, sinus VV' alternans triplets on near-field electrograms independently predict nonarrhythmic death rather than ventricular tachyarrhythmias.
Answers are grounded in this paper and cite their sources.
VV' alternans may flag nonarrhythmic mortality risk on ICD electrograms; hypothesis-generating and requires prospective validation before clinical use.
BACKGROUND: In heart failure patients with implantable cardioverter defibrillator (ICD) the risk of death from causes other than tachyarrhythmia is substantial. Benefit from ICD is determined by two competing risks: appropriate ICD shock or nonarrhythmic death. The goal of the study was to test predictors of competing outcomes. METHODS: Patients with structural heart disease (N = 234, mean age 58.5 ± 15.1; 71% men, 80% whites, 61% ischemic cardiomyopathy) and primary (75%) or secondary prevention ICD underwent a 5-minute baseline near-field electrogram (NF EGM) recording. VV' alternans triplets were quantified as a percentage of three sinus VV' cycles sequences of "short-long-short" or "long-short-long" order. Appropriate ICD shock for fast ventricular tachycardia (FVT, cycle length ≤240 ms)/ventricular fibrillation (VF) and composite nonarrhythmic death (pump failure death or heart transplant) served as competing outcomes. RESULTS: Over a median follow-up of 2.4 years, 26 patients (4.6% per person-year of follow-up) developed FVT/VF with ICD shock, and 35 (6.3% per person-year of follow-up) had nonarrhythmic death. In competing risk analysis, after adjustment for demographics, left ventricular ejection fraction, New York Heart Association class, cardiomyopathy type, use of class I antiarrhythmics, and diabetes, increased percentage of VV' alternans triplets (>69%) was associated with nonarrhythmic death (subhazard ratio [SHR] 2.09; 95% confidence interval [CI] 1.03-4.23; P = 0.041), rather than with FVT/VF (SHR 1.05; 95% CI 0.45-2.46; P = 0.901). Risk of nonarrhythmic death was especially high in diabetics with VV' alternans triplets in the highest quartile (SHR 3.46; 95% CI 1.41-8.50; P = 0.007). CONCLUSION: In ICD patients with structural heart disease sinus VV' alternans triplets on NF EGM is independently associated with nonarrhythmic death, rather than with FVT/VF.
No takes yet. Share an insight, caveat, or question.
Baumert et al. (2015) studied this question.