Key result
During left bundle branch pacing, a QRS axis > -30° was significantly associated with a paced QRS duration < 120 ms (OR 5.79; 95% CI 2.40-13.93; p=0.001).
Why the study?
LBBP can be achieved at various anatomical sites within the interventricular septum, influencing paced QRS duration, but whether paced QRS axis and inferior lead polarity associate with shorter QRS duration was unclear.
Do paced QRS axis and polarity in inferior leads predict a shorter paced QRS duration during left bundle branch pacing in patients referred for LBBP?
Observational (n=125)
Do paced QRS axis and polarity in inferior leads predict a shorter paced QRS duration during left bundle branch pacing in patients referred for LBBP?
Odds Ratio: 5.79 (95% CI 2.4–13.93)
p-value: p=0.001
During left bundle branch pacing, a QRS axis > -30° and an intermediate final polarity in inferior leads are associated with a shorter paced QRS duration, providing novel criteria for optimizing pacing results.
Suggests inferior lead polarity may help optimize left bundle branch pacing sites; leaves open.
BACKGROUND: Left bundle branch pacing (LBBP) may be achieved in various anatomical sites within the interventricular septum (IVS), thus influencing paced QRS duration (QRSd).The purpose of this study was to determine whether paced QRS axis (QRSâ) and predominant polarity in inferior leads could be associated with a shorter paced QRSd. METHODS: We analyzed paced QRSd, QRSâ, polarity in inferior leads, and IVS thickness in patients referred for LBBP. Three paced morphology patterns in the inferior leads were considered: All positive (P), all negative (N) and intermediate (combination of isoelectric, positive, and negative complexes, (I). Patients were divided into two groups according to a paced QRSd < 120 or ≥ 120 ms. RESULTS: A total of 125 patients were included (age 76 ± 10 years, 46% female). Mean baseline QRSâ was 8 ± 37°. Paced QRSd was significantly shorter as compared to baseline (120 ± 10 vs. 127 ± 33 ms; p = .017) and significantly different according to paced QRS morphology pattern in the inferior leads (P 49%, 119 ± 9; N 30%, 126 ± 12; I 21%; 113 ± 10 ms; p < .001) or paced QRSâ (Normal 59%, 116 ± 1; Right 6%, 129 ± 1; Left 35%, 124 ± 11 ms; p < .001). On multivariate analysis, a QRSâ > -30°(OR 5.79 [2.40-13.93; 95% CI] p = .001), an Intermediate pattern in inferior leads (OR 3.00 [1.67-8.43; 95% CI] p = .037), and an IVS thickness ≤ 10 mm (OR 2.59 [1.10-6.10; 95% CI]; p = .029) were significantly associated with a paced QRSd < 120 ms. CONCLUSIONS: During LBBP, a QRSâ > -30° and intermediate final polarity in inferior leads are associated with a shorter paced QRSd.
No takes yet. Share an insight, caveat, or question.
Campal et al. (2023) conducted an observational in Patients referred for left bundle branch pacing (n=125). QRS axis > -30° during left bundle branch pacing vs. Other QRS axis patterns was evaluated on Paced QRS duration < 120 ms (OR 5.79, 95% CI 2.40-13.93, p=0.001). During left bundle branch pacing, a QRS axis > -30° was significantly associated with a paced QRS duration < 120 ms (OR 5.79; 95% CI 2.40-13.93; p=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: