Key result
Simple manual traction achieves uncomplicated transvenous lead removal in ~91% of CIED extraction procedures.
Why the study?
The need for cardiac device lead extractions is increasing, and while advanced technological tools such as powered laser sheaths aim to improve outcomes, they are expensive and technically challenging, prompting evaluation of simple manual traction.
Observational (n=35)
No
Simple manual traction remains an effective first-line approach for transvenous lead extraction, achieving a 90% success rate without complications.
Answers are grounded in this paper and cite their sources.
May support manual traction as initial approach in select cases; leaves open randomized comparison to extraction tools.
INTRODUCTION: Indications for cardiac devices have been increasing as well as the need for lead extractions as a result of infections, failed leads and device recalls. Powered laser sheaths, with a global trend towards the in-creasingly technological tools, meant to improve the procedure's outcome but have economic implications. OBJECTIVE: The aim of this study is to demonstrate the experience of a Bra-zilian center that uses simple manual traction in most lead removals per-formed annually, questioning the real need for expensive and technically challenging new devices. METHODS: This retrospective observational study included 35 patients who had a transvenous lead extraction in the period of a year between January 1998 and October 2014 at Hospital de Messejana Dr. Carlos Alberto Studart Gomes, in Fortaleza, CE, Brazil. Data were collected through a records review. They were evaluated based on age, type of device, dwelling time, indication for removal, technique used and immediate outcomes. RESULTS: The median dwelling time of the devices was 46.22 months. Infec-tion, lead fracture and device malfunction were the most common indica-tions. Simple traction was the method of choice, used in 88.9% of the pro-cedures. Manual traction presented high success rates, resulting in com-plete removal without complications in 90% of the cases. CONCLUSION: This article suggests that lead extraction by simple manual traction can still be performed effectively in countries with economic diffi-culties as a first attempt, leaving auxiliary tools for a second attempt in case of failure or contraindications to the simple manual traction technique.
No takes yet. Share an insight, caveat, or question.
Lima et al. (2019) conducted an observational in Cardiac implantable electronic device (CIED) complications requiring transvenous lead extraction (infection, lead fracture, or device malfunction) (n=35). Simple manual lead traction was evaluated on Complete lead removal without complications. Simple manual traction achieved complete transvenous lead removal without complications in 90.6% (29/32) of procedures among patients with cardiac implantable electronic device complications.
Synapse has enriched 10 related papers. Consider them for comparative context: