Key result
MR-proANP demonstrated a pooled sensitivity of 90% (95% CI: 88-91%) and specificity of 68% (95% CI: 66-70%) for diagnosing heart failure in patients presenting to the ED with acute dyspnea.
Why the study?
This study aimed to review the diagnostic value of MR-proANP for heart failure in patients presenting to the emergency department with acute dyspnoea.
Does MR-proANP testing accurately diagnose heart failure in patients presenting to the emergency department with acute dyspnea?
Meta-Analysis (n=3,811)
Does MR-proANP testing accurately diagnose heart failure in patients presenting to the emergency department with acute dyspnea?
Odds Ratio: 18.97 (95% CI 11.73–30.68)
MR-proANP demonstrates high sensitivity (90%) and moderate specificity (68%) for diagnosing heart failure in patients with acute dyspnea in the emergency department.
Supports ruling out heart failure in acute dyspnea; confirms MR-proANP diagnostic utility via meta-analysis.
Objectives: This study aimed to review the diagnostic value of mid-regional pro-atrial natriuretic peptide (MR-proANP) for heart failure (HF) in patients who presented to the emergency department (ED) with acute dyspnoea.Methods: Relevant studies were searched on the databases of PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials, with publication date limited to 30 March 2018. Literature identification, quality assessment, data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Individual and pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were calculated.Results: A total of eight studies were retrieved, involving 1562 HF patients and 2249 non-HF patients. The sensitivity for each included study ranged from 80 to 97%, with a pooled sensitivity of 90% (95% CI: 88–91%), while the specificity ranged from 37 to 86%, with a pooled specificity of 68% (95% CI: 66–70%). The pooled PLR for included studies was 2.88(95% CI: 2.12–3.93), with a pooled NLR of 0.16 (95% CI: 0.11–0.24), and a pooled DOR of 18.97 (95% CI: 11.73–30.68).Conclusions: With a decent sensitivity, MR-proANP is a useful biomarker for correctly identifying HF in patients with acute dyspnoea.
No takes yet. Share an insight, caveat, or question.
Wen et al. (2019) conducted a meta-analysis in Heart failure in patients with acute dyspnea (n=3,811). MR-proANP was evaluated on Diagnosis of heart failure (DOR 18.97, 95% CI 11.73-30.68). MR-proANP demonstrated a pooled sensitivity of 90% (95% CI: 88-91%) and specificity of 68% (95% CI: 66-70%) for diagnosing heart failure in patients presenting to the ED with acute dyspnea.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: