Why the study?
Do the evaluated RT-PCR assays accurately detect and differentiate seasonal and 2009 H1N1 influenza viruses in pediatric respiratory specimens?
Do the evaluated RT-PCR assays accurately detect and differentiate seasonal and 2009 H1N1 influenza viruses in pediatric respiratory specimens?
The CDC influenza A/B assay and a newly developed 2009 H1N1 RT-PCR assay can be combined to accurately detect seasonal influenza and specifically identify the 2009 H1N1 strain.
Answers are grounded in this paper and cite their sources.
Supports combined CDC and H1N1 RT-PCR for pediatric influenza detection; leaves open validation in larger diverse cohorts before routine use.
The performance characteristics of three real-time influenza A/B virus reverse transcription-PCR (RT-PCR) assays and two real-time 2009 H1N1 RT-PCR assays were evaluated using previously characterized clinical specimens. A total of 150 respiratory specimens from children (30 influenza A/H1 virus-, 30 influenza A/H3 virus-, 30 2009 H1N1-, and 30 influenza B virus-positive specimens and 30 influenza virus-negative specimens) were tested with the CDC influenza A/B PCR (CDC), ProFlu(+) multiplex real-time RT-PCR assay (ProFlu(+)), and MGB Alert Influenza A/B & RSV RUO (MGB) assays. A second set of 157 respiratory specimens (100 2009 H1N1-, 22 seasonal influenza A/H1-, and 15 seasonal influenza A/H3-positive specimens and 20 influenza-negative specimens) were tested with a new laboratory-developed 2009 H1N1 RT-PCR and the CDC 2009 H1N1 assay. The overall sensitivities of the CDC, ProFlu(+), and MGB assays for detection of influenza A and B viruses were 100%, 98.3%, and 94%, respectively. The ProFlu(+) assay failed to detect one influenza A/H1 virus-positive specimen and yielded one unresolved result with another influenza A/H1 virus-positive specimen. The MGB assay detected 84/87 (96.5%) of influenza A and B viruses and 26/30 (86.6%) of 2009 H1N1 viruses. The new laboratory-developed 2009 H1N1 RT-PCR assay detected 100/100 (100%) 2009 H1N1 virus-positive specimens, while the CDC SW Inf A and SW H1 PCR assays failed to detect one and three low-positive 2009 H1N1-positive specimens, respectively. The CDC influenza A/B virus assay and the newly developed 2009 H1N1 RT-PCR assay with an internal control can be set up in two separate reactions in the same assay for routine clinical testing to detect influenza A and B viruses and to specifically identify the 2009 H1N1 influenza virus.
No takes yet. Share an insight, caveat, or question.
Selvaraju et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: