Key result
Preliminary dosimetric analysis of 801 paediatric cardiac catheterisation procedures in the Coccinelle cohort revealed mean effective doses of 4.8 mSv for diagnostic and 7.3 mSv for therapeutic interventions.
Why the study?
Does ionising radiation exposure from paediatric cardiac catheterisation increase the risk of leukaemia and solid cancers in children?
Cohort (n=4,500)
Yes
Does ionising radiation exposure from paediatric cardiac catheterisation increase the risk of leukaemia and solid cancers in children?
The Coccinelle study will provide large-scale epidemiological data on the long-term cancer risks associated with radiation exposure from pediatric cardiac catheterization.
Answers are grounded in this paper and cite their sources.
Substantial doses in paediatric catheterisation warrant minimization; supports long-term cancer risk evaluation in the Coccinelle cohort.
Cardiac catheterisation has become an essential tool in the diagnosis and treatment of children with a wide variety of congenital and acquired forms of cardiovascular disease. Despite the clear clinical benefit to the patient, radiation exposure from paediatric cardiac catheterisation procedures (CCPs) may be substantial. Given children's greater sensitivity to radiation and the longer life span during which radiation health effects can develop, an epidemiological cohort study, named Coccinelle or 'Ladybird' (French acronym for 'Cohorte sur le risque de cancer après cardiologie interventionnelle pédiatrique'), is carried out in France to evaluate the risks of leukaemia and solid cancers in this population. A total number of 8000 included children are expected. Individual CCP-related doses will be assessed for each child included in the cohort. For each CCP performed, dosimetric parameters (dose-area product, fluoroscopy time and total number of cine frames) are retrieved retrospectively. Organ doses, especially to the lung, the oesophagus and the thyroid, are calculated with PCXMC software. The cohort will be followed up through linkage with French paediatric cancer registries.
No takes yet. Share an insight, caveat, or question.
Baysson et al. (2015) conducted a cohort in Congenital and acquired cardiovascular disease requiring cardiac catheterisation (n=4,500). Ionising radiation from cardiac catheterisation vs. Unexposed or lower dose exposure was evaluated on Risks of leukaemia and solid cancers (incidence). Preliminary dosimetric analysis of 801 paediatric cardiac catheterisation procedures in the Coccinelle cohort revealed mean effective doses of 4.8 mSv for diagnostic and 7.3 mSv for therapeutic interventions.
Synapse has enriched 10 related papers. Consider them for comparative context: