Why the study?
Does catheter tip position influence block height in continuous spinal anesthesia for elderly patients undergoing hip surgery?
Does catheter tip position influence block height in continuous spinal anesthesia for elderly patients undergoing hip surgery?
In continuous spinal anesthesia, the final position of the catheter tip does not influence the distribution of hypobaric local anesthetics, but inaccurate lumbar puncture level determination poses a risk of spinal cord damage.
Answers are grounded in this paper and cite their sources.
Emphasizes precise lumbar puncture level over tip adjustment; case report leaves open optimal continuous spinal techniques.
The purpose of this study was to investigate the incidence of technical problems encountered when performing continuous spinal anesthesia and the influence of catheter tip position on block height following injection of a hypobaric spinal anesthetic. Twenty-nine elderly patients undergoing hip surgery were studied. Lumbar puncture was performed with an 18-gauge Tuohy needle at the L3–4 (or L2–3) interspace. Threading was defined as easy if a 20-gauge catheter was inserted on the first try, 3–4 cm cephalad. Threading was considered difficult if cephalad insertion of the catheter was impossible on the first try; the Tuohy needle was then rotated with its bevel facing caudally, the catheter inserted for 1–2 mm, and the needle turned back cephalad together with the catheter partially threaded, for further cephalad insertion up to 4 cm. All patients received 7.5 mg of hypobaric bupivacaine or tetracaine in the lateral decubitus position and sensory levels were determined by pinprick. After surgery all catheters were injected with radiographic dye and examined by radiograph for verification of position. The determination of the level of lumbar puncture was falsely judged in 59% of cases, the puncture being performed 1 or 2 spaces higher than assumed. Although threading difficulties were encountered in 4/28 cases, there was a 100% success rate in catheter insertion. One catheter displacement into the epidural space was noted. Twenty of twenty-eight catheters took a cephalad direction, 6 remained coiled in a horizontal position, and 2 took a caudal direction. Finally, no correlation was found between the position of the tip of the catheter and the sensory levels achieved with the same dose of local anesthetic. We conclude that the direction taken by the catheter cannot be anticipated, and that the final position of its tip does not influence the distribution of hypobaric local anesthetics in the subarachnoid space. However, the high incidence of inadequate determination of the level of lumbar puncture, associated with the cephalad threading of a catheter, can represent a potential risk of damage to the spinal cord. Furthermore, the use of the maneuver previously described and performed in the 4 cases of difficult threading can not be recommended because one adds the risk of catheter shearing.
No takes yet. Share an insight, caveat, or question.
Gessel et al. (1993) studied this question.