A novel motion tracking algorithm for cardiac 4D-CT accurately measured transmitral and left atrial appendage flow rates, demonstrating good agreement with 4D flow MRI, including a bias of -6 ml/s for peak LAA outflow.
Why the study?
Accurate validated techniques to extract blood flow information, such as transmitral and left atrial appendage flow, from cardiac 4D-CT have been lacking.
Does a novel motion tracking algorithm for 4D-CT accurately measure transmitral and LAA flow rates compared to 4D flow MRI in patients undergoing coronary CT angiography?
Observational (n=9)
No
Does a novel motion tracking algorithm for 4D-CT accurately measure transmitral and LAA flow rates compared to 4D flow MRI in patients undergoing coronary CT angiography?
A novel motion tracking algorithm for 4D-CT can accurately measure transmitral and LAA flow rates, showing good agreement with 4D flow MRI, which may aid in assessing diastolic dysfunction and stroke risk.
Answers are grounded in this paper and cite their sources.
4D-CT flow extraction feasible vs MRI in small cohorts; leaves open larger validation before clinical adoption for diastolic or AF assessment.
BACKGROUND: Cardiac time-resolved CT (4D-CT) acquisitions provide high quality anatomical images of the heart. However, some cardiac diseases require assessment of blood flow in the heart. Diastolic dysfunction, for instance, is diagnosed by measuring the flow through the mitral valve (MV), while in atrial fibrillation, the flow through the left atrial appendage (LAA) indicates the risk for thrombus formation. Accurate validated techniques to extract this information from 4D-CT have been lacking, however. METHODS: To measure the flow rate though the MV and the LAA from 4D-CT, we developed a motion tracking algorithm that performs a nonrigid deformation of the surface separating the blood pool from the myocardium. To improve the tracking of the LAA, this region was deformed separately from the left atrium and left ventricle. We compared the CT based flow with 4D flow and short axis MRI data from the same individual in 9 patients. RESULTS: For the mitral valve flow, good agreement was found for the time span between the early and late diastolic peak flow (bias: <0.1 s). The ventricular stroke volume is similar compared to short-axis MRI (bias 3 ml). There are larger differences in the diastolic peak flow rates, with a larger bias for the early flow rate than the late flow rate. The peak LAA outflow rate measured with both modalities matches well (bias: -6 ml/s). CONCLUSIONS: Overall, the developed algorithm provides accurate tracking of dynamic cardiac geometries resulting in similar flow rates at the MV and LAA compared to 4D flow MRI.
No takes yet. Share an insight, caveat, or question.
Bäck et al. (2023) conducted an observational in Chest pain (undergoing coronary CT angiography) (n=9). Cardiac 4D-CT based motion tracking algorithm vs. 4D flow MRI and short axis MRI was evaluated on Agreement of transmitral and left atrial appendage flow rates between 4D-CT and MRI (bias 3 ml for ventricular stroke volume; bias -6 ml/s for peak LAA out flow rate). A novel motion tracking algorithm for cardiac 4D-CT accurately measured transmitral and left atrial appendage flow rates, demonstrating good agreement with 4D flow MRI, including a bias of -6 ml/s for peak LAA outflow.