Synapse
⌘+K
Synapse
PulseExploreClubsResearchersJournals
Instagram
HomeClubsExplore
July 1, 1997Echocardiography

TTE highly correlates with TEE for LAA flow velocity, detecting low flow with 88% sensitivity.

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Does transthoracic echocardiography accurately measure flow velocity in the left atrial appendage compared to transesophageal echocardiography in patients undergoing echocardiographic study?

Population

30 consecutive patients sent for echocardiographic study with diagnoses including stroke, mitral stenosis…

Comparison

Transthoracic echocardiography measurement of… vs Transesophageal echocardiography measurement of…

Design

Cross-sectional

Key result

Transthoracic echocardiography was highly correlated with transesophageal echocardiography for measuring left atrial appendage flow velocity (r=0.95) and detected FV <30 cm/sec with 88% sensitivity.

Authors

CCCésar CarranzaAAAlejandro AbufheleFCFanny D. Cartes

Discussion

Loading...

Member takes

Overview

May support noninvasive TTE for LAA velocity; leaves open prospective outcome validation before clinical use.

Study Design

Type

Cross-Sectional (n=30)

Structured PICO

Does transthoracic echocardiography accurately measure flow velocity in the left atrial appendage compared to transesophageal echocardiography in patients undergoing echocardiographic study?

P
Population
30 consecutive patients (mean age 55 years) referred for echocardiography for various indications including stroke and mitral stenosis.
E
Exposure
Transthoracic echocardiography (TTE) measurement of flow velocity in the left atrial appendage
C
Comparator
Transesophageal echocardiography (TEE) measurement of flow velocity in the left atrial appendage
O
Outcome
Flow velocity measurements in the left atrial appendagesurrogate

Main Result

Effect estimate: r = 0.95

Absolute Event Rate: 32.7% vs 33.7%

p-value: p=NS

Transthoracic echocardiography provides flow velocity measurements in the left atrial appendage that correlate highly with transesophageal echocardiography, offering a potential non-invasive alternative for assessing systemic embolic risk.

Cite This Study

Carranza et al. (1997) conducted a cross-sectional in Patients referred for echocardiography (n=30). Transthoracic echocardiography (TTE) vs. Transesophageal echocardiography (TEE) was evaluated on Mean flow velocity in the outlet of the left atrial appendage (cm/sec) (r = 0.95, p=NS). Transthoracic echocardiography was highly correlated with transesophageal echocardiography for measuring left atrial appendage flow velocity (r=0.95) and detected FV <30 cm/sec with 88% sensitivity.

synapsesocial.com/papers/6aa25811da8566d019e56528https://doi.org/10.1111/j.1540-8175.1997.tb00735.x
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Transthoracic Doppler echocardiography for the assessment of left atrial appendage size and blood flow velocity. A multicentre study2008 · 6 citations
  2. 2Transthoracic Doppler echocardiographic measurement of left atrial appendage blood flow velocity: comparison with transoesophageal measurement2003 · 18 citations
  3. 3Assessment of left atrial appendage function with transthoracic tissue Doppler echocardiography2009 · 74 citations
  4. 4Multiplane Transesophageal Echocardiographic Assessment of Left Atrial Appendage2002 · 3 citations
  5. 5Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke2017 · 8 citations