Why the study?
Does transthoracic echocardiography accurately measure left atrial appendage blood flow velocity compared to transoesophageal echocardiography in patients with cardiac diseases?
Does transthoracic echocardiography accurately measure left atrial appendage blood flow velocity compared to transoesophageal echocardiography in patients with cardiac diseases?
Transthoracic echocardiography can reliably assess left atrial appendage flow velocities, demonstrating excellent correlation with transoesophageal echocardiography in patients with sinus rhythm or atrial fibrillation.
Answers are grounded in this paper and cite their sources.
TTE may enable noninvasive LAA velocity assessment; leaves open prospective outcome validation before clinical adoption.
AIM: We validated transthoracic echocardiographic measurements of left atrial appendage flow velocity by comparing them with transoesophageal echocardiographic measurements. METHODS AND RESULTS: Eighty-four consecutive patients (mean age, 64.6 years) with various cardiac diseases, who underwent both transthoracic echocardiography and transoesophageal echocardiography were studied. Thirty-two patients were in sinus rhythm, and the remaining 52 patients were in atrial fibrillation. On transthoracic echocardiography, the transducer was placed somewhat superior and outside from the position viewing the conventional parasternal short-axis image of the aortic valve, so that the angle between left atrial appendage midline and Doppler beam could be narrowed. The left atrial appendage flow velocity pattern was recorded by pulsed Doppler mode with a sampling volume placed at the left atrial appendage orifice on both transthoracic echocardiography and transoesophageal echocardiography. In both approaches, the peak emptying velocity (LAA-E) and the peak filling velocity (LAA-F) of the left atrial appendage were measured. In sinus rhythm, the LAA-E was detectable in 25 of the 32 patients (78.1%) and the LAA-F in 20 of the 32 patients (62.5%). Both LAA-E and LAA-F were detectable in 46 of the 52 patients (88.5%) in atrial fibrillation. Good correlations of LAA-E and LAA-F were observed between transthoracic echocardiography and transoesophageal echocardiography measurements in sinus rhythm (r=0.94, r=0.95, respectively; both, P<0.0001) and in atrial fibrillation (r=0.89, r=0.95, respectively; both, P<0.0001). CONCLUSIONS: The left atrial appendage flow velocities could be sufficiently recorded and assessed by transthoracic echocardiography in 84 Japanese unselected consecutive patients with sinus rhythm or atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Nobuo Fukuda (2003) studied this question.