Why the study?
With increasing use of photoplethysmography (PPG) in wearable devices, the optimal index finger (right or left) for PPG data acquisition and filtration remained to be discerned.
Does PPG signal acquisition from the right index finger improve the signal-to-noise ratio compared to the left index finger in healthy individuals?
Does PPG signal acquisition from the right index finger improve the signal-to-noise ratio compared to the left index finger in healthy individuals?
The right index finger may be superior to the left for PPG signal acquisition, yielding a higher signal-to-noise ratio when subjected to filtration.
Right index finger may offer modestly higher PPG SNR post-filtering; leaves open optimal site selection for wearables pending broader validation.
Photoplethysmography (PPG) has emerged as an increasingly attractive signal for noninvasive physiological measurements, owing to its simplicity, cost-effectiveness, and broad applicability spanning cardiovascular to respiratory systems. The burgeoning interest in PPG signal processing has facilitated its extensive incorporation in wearable devices, thus stimulating active research in this field. The present study undertakes a comprehensive evaluation to discern the optimal index finger (right or left) for PPG data acquisition and subsequent filtration, appraised through the lens of the signal-to-noise ratio (SNR) of the filtered signal. An analysis conducted on signals contaminated with white Gaussian noise unveiled that the Savitzky-Golay filter (a polynomial filter) with a window size of three outperformed other window lengths, rendering the highest SNR. Among the Infinite Impulse Response (IIR) filters compared; the Chebyshev I filter emerged as superior. Interestingly, the right index finger consistently demonstrated a higher mean SNR across filters: 0.49% for the Savitzky-Golay filters, 4.32% for the Butterworth (order 6), 7.71% for the Chebyshev I (order 10), and 4.02% for the Chebyshev II (order 4), relative to the left index finger for PPG signals perturbed by white Gaussian noise. These findings provide an insightful perspective for future research and development in wearable devices, suggesting potential superiority of the right index finger for PPG signal acquisition and filtration.
No takes yet. Share an insight, caveat, or question.
Kanwal et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: