Why the study?
Data directly comparing the effectiveness and safety of transvenous extraction of single- versus dual-coil ICD leads were lacking.
Does transvenous extraction of dual-coil ICD leads have similar safety and effectiveness compared to single-coil leads in patients requiring ICD lead removal?
Does transvenous extraction of dual-coil ICD leads have similar safety and effectiveness compared to single-coil leads in patients requiring ICD lead removal?
Answers are grounded in this paper and cite their sources.
Transvenous extraction of dual-coil ICD leads is comparably safe and effective to single-coil leads, though it requires longer fluoroscopy time and more frequent use of advanced tools.
The available literature lacks data concerning direct comparison of the effectiveness and safety of single- versus dual-coil implantable cardioverter-defibrillator (ICD) leads transvenous extraction. Certainly, additional shocking coil in superior vena cava adds to the amount of metal in the vascular system. Adhesions developing around the superior vena cava coil add to the difficulty of extraction of ICD lead if lead removal is required. The aim of the study was to assess the effectiveness and safety of single- and dual-coil ICD leads transvenous extraction using mechanical systems. We performed transvenous lead extraction (TLE) of 197 ICD leads in 196 patients. There were 46 (23.3%) dual-coil leads removed from 46 (23.5%) patients. Cardiovascular implantable electronic device-related infection was an indication for TLE in 25.0% of patients. The following extracting techniques were used: manual direct traction, mechanical telescopic sheaths, controlled-rotation mechanical sheaths, and femoral approach. Complete ICD lead removal and complete procedural success in both groups were similar (99.3% in single-coil vs 97.8% in dual-coil, P = .41 and 99.3% in single-coil vs 97.8% in dual-coil, P = 0.41, respectively). We did not find significant difference between major and minor complication rates in both groups (2.0% in single-coil vs 4.3% in dual-coil, and 0.7% in single-coil vs 0.0% in dual-coil, P = .58, respectively). There was 1 death associated with the TLE procedure of single-coil lead.This study shows that extraction of dual-coil leads seems to be comparably safe and effective to extraction of single-coil leads. On the other hand, it requires longer fluoroscopy time and frequent utilization of advanced tools.
No takes yet. Share an insight, caveat, or question.
Ząbek et al. (2019) studied this question.