Answers are grounded in this paper and cite their sources.
This paper introduces a digital adaptive control method for a bidirectional dc/dc charger/discharger, which is the core element for reliable and efficient energy storage systems. The proposed method achieves zero-voltage switching (ZVS) without the use of an auxiliary zero-crossing detection (ZCD) circuit. To satisfy ZVS conditions, proper switching frequency is determined through a digital calculation. It features soft switching over wide input and output ranges. Because this method does not require a ZCD circuit, it is easily implemented with bidirectional operation and reduces instability and noise susceptibility problems. To reduce conduction loss, a multiphase interleaving technique is applied. This interleaving method reduces the required capacitance by decreasing the current ripple. A phase shedding technique is also implemented to achieve higher efficiency over a wide load range. The operation of the proposed digital adaptive control method is analyzed. For experimental verification, a 200-W two-phase-interleaved bidirectional synchronous buck converter with 30-38-V bus voltage and 15-25-V battery voltage is implemented.
No takes yet. Share an insight, caveat, or question.
Baek et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: