Why the study?
Does the 125I Fibrinogen Uptake Test accurately diagnose deep vein thrombosis compared to phlebography in patients at risk for thromboembolism?
Does the 125I Fibrinogen Uptake Test accurately diagnose deep vein thrombosis compared to phlebography in patients at risk for thromboembolism?
The 125I Fibrinogen Uptake Test is an accurate method for diagnosing deep vein thrombosis, showing 80% agreement with phlebography.
Answers are grounded in this paper and cite their sources.
May support FUT for DVT diagnosis; leaves open prospective validation before practice change.
The fibrinogen labeled with radioactive iodine (125I) uptake test (FUT) is an established clinical test at St. Thomas's Hospital, London. It is performed with the patient in the supine position, with use of the Negus technique, with a collimator aperture of 3 inches, and scintillation counter connected to a scaler and timer. In studying 102 patients with the FUT and phlebography, the FUT findings agreed with those of phlebography in 80% of the limbs. Thus, the FUT is an accurate method for diagnosing deep vein thrombosis between the junction of the middle and upper thirds of the thigh and the lower calf. The test is currently used in screening of patients considered to be at risk for thromboembolism.
No takes yet. Share an insight, caveat, or question.
N L Browse (1972) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: