The paper refers to determinations of the dispersion of F -values in the range of the L absorption levels, in which powder methods were applied to measurements requiring a high degree of accuracy and discusses the conditions determining quantitative measurements made with microcrystalline powders. The absorption in a powder layer and the effect of the size of the crystallites on the evaluation of intensities are discussed. Indications are made as to the preparation of suitable particles and as to the use of spacing materials for avoiding the formation of larger units. A detailed discussion is given of the factors determining quantitative measurements by the method of the flat powder layer and by the method of mixed powders. The conditions determining the accuracy of the microphotometric photometry of reflections obtained from a flat layer and the absorption effect in a mixed layer in relation to the absorption in the individual particle are considered. Expressions are derived for evaluating the absorption effect for particles of different absorbing-power. Reference is made to a recent paper by Brindley and Spiers on a development of the method of the flat powder layer and of the method of mixed layers. It is shown that this particular procedure which had been described by the writer in an earlier paper is not advisable for accurate measurements.
No takes yet. Share an insight, caveat, or question.
J. C. M. Brentano (1935) studied this question.