Key result
18F-FDG-PET scanning successfully confirmed an intracardiac device-lead infection caused by the slow-growing pathogen Abiotrophia defectiva in a 65-year-old male.
Why the study?
Can 18F-FDG-PET scanning confirm intracardiac device-lead infection caused by slow-growing pathogens like Abiotrophia defectiva?
Case Report (n=1)
Can 18F-FDG-PET scanning confirm intracardiac device-lead infection caused by slow-growing pathogens like Abiotrophia defectiva?
Positive 18F-FDG-PET findings are highly suggestive of ICD-lead infection, even for low-grade infections caused by slow-growing pathogens like Abiotrophia defectiva.
Answers are grounded in this paper and cite their sources.
May support 18F-FDG-PET for device-lead infections by slow-growing pathogens; hypothesis-generating and requires prospective validation.
Abiotrophia species are relatively slow growing pathogens, which may be present as commensal flora. However, invasive infections are frequently reported, like endocarditis, septic arthritis, osteomyelitis, and many other types of infection. In this case report we describe a 65-year-old male patient with an intracardiac device- (ICD-) lead infection caused by Abiotrophia defectiva. Diagnosis was confirmed by (18)F-FDG-PET scanning. This is remarkable, since Abiotrophia defectiva is a slow growing pathogen causing low-grade infections. This case demonstrates that although infection of ICD-leads cannot be excluded in case of (18)F-FDG-PET-negative findings, positive findings are highly suggestive for infection.
No takes yet. Share an insight, caveat, or question.
Roeden et al. (2016) conducted a case report in Intracardiac device-lead infection caused by Abiotrophia defectiva (n=1). 18F-FDG-PET scanning was evaluated. 18F-FDG-PET scanning successfully confirmed an intracardiac device-lead infection caused by the slow-growing pathogen Abiotrophia defectiva in a 65-year-old male.
Synapse has enriched 10 related papers. Consider them for comparative context: