Key result
Viscoelastic hemostatic analyzers provided a fast, portable alternative to D-dimers for detecting in vitro fibrinolysis, with high sensitivity and specificity.
Why the study?
Fibrinolysis is associated with poor outcomes without early, effective treatment, necessitating evaluation and comparison of fibrinolysis detection capabilities across different viscoelastic hemostatic analyzers, assays, and D-dimers.
Do viscoelastic hemostatic analyzers provide comparable sensitivity and specificity to D-dimers for detecting in vitro fibrinolysis?
Do viscoelastic hemostatic analyzers provide comparable sensitivity and specificity to D-dimers for detecting in vitro fibrinolysis?
Viscoelastic hemostatic analyzers can serve as a fast, effective, and portable alternative to D-dimers for the rapid detection of fibrinolysis.
Answers are grounded in this paper and cite their sources.
VHA comparisons for tPA-induced fibrinolysis detection warrant cautious interpretation; leaves open clinical utility pending prospective validation.
Fibrinolysis is a critical component of hemostasis associated with poor outcomes if not treated early and effectively. Successful hemostasis management requires close fibrinolysis monitoring. The study aimed to compare the fibrinolysis detection capabilities of different viscoelastic hemostatic analyzers (VHA) and assays, including the new generation cartridge-based devices, and D-dimers under standardized conditions in vitro. Tissue plasminogen activator (tPA) induced fibrinolysis was assessed with D-dimers, TEG®6s (new generation; n = 160 samples) and TEG®5000 (older generation; n = 140 samples) at 30 min after maximum amplitude (MA, LY30) for the RapidTEG® (CRT) and Kaolin (CK) assays, and at 30 min after clotting time (CT; LI30) for the ROTEM® Sigma and ROTEM® Delta (new and older generations, n = 160 and n = 140 respectively) INTEM and EXTEM assays. Both VHA analyzers showed a monotonic relationship between lysis at 30 min and increased tPA concentrations. D-dimers had the highest sensitivity for detecting fibrinolysis compared with the VHA assays, however they had lower specificity at the highest tPA concentrations. Variance between duplicate measurements in the new generation devices was 1.6–3.7% for TEG®6s and 11.9–15.8% with ROTEM® Sigma. All VHA devices identified lower fibrinolysis levels than currently used in published treatment algorithms. Differences were observed between intrinsic versus extrinsic pathway activated assays in the ability to detect tranexamic acid fibrinolysis reversal. The results show that while D-dimers are more sensitive at detecting in vitro fibrinolysis, VHA devices could be used as a fast, effective, and portable alternative to detect fibrinolysis rapidly, with high sensitivity and specificity.
No takes yet. Share an insight, caveat, or question.
Dias et al. (2021) studied Fibrinolysis (n=300). Viscoelastic hemostatic analyzers (VHA) vs. D-dimers was evaluated on Fibrinolysis detection capability. Viscoelastic hemostatic analyzers provided a fast, portable alternative to D-dimers for detecting in vitro fibrinolysis, with high sensitivity and specificity.