Radiation beams from multicurie Co60 sources are widely used for instrument calibration and for radiation treatment. It is often assumed for purposes of analysis that such beams contain only the 1.17 and 1.33 MeV γ-rays. However, it is recognised that this assumption is not strictly valid because of the energy degradation due to Compton scattering in the source material and the source collimator. A scintillation spectrometer with a 5-in-dia. by 4-in-long sodium iodide crystal has been used to determine the amount and energy of the scattered radiation as well as its variation with source dimensions and collimator geometry. Since the sources currently in common use have appreciable mass, source scattering is a far greater contributor of degraded radiation than is the collimator. Thus for multicurie sources, minimization of scatter involves primarily an increase in specific activity. The scattered intensity from the sources investigated ranges from 3.3 to 14.6 per cent of the intensity in the primary beam. Quantitative data are presented.