Key result
Use of a bioresorbable-polymer sirolimus-eluting stent compared to a durable-polymer everolimus-eluting stent reduced medical costs by $124 per patient and gained 0.000017 QALYs over 12 months.
Why the study?
The study sought to estimate the health economic impact of an ultrathin, bioresorbable-polymer sirolimus-eluting stent following findings of lower target lesion failure and peri-procedural myocardial infarction compared to a durable-polymer everolimus-eluting stent.
Does an ultrathin, bioresorbable-polymer sirolimus-eluting coronary stent reduce medical costs and improve quality-adjusted life-years compared to a thin, durable-polymer everolimus-eluting stent?
Does an ultrathin, bioresorbable-polymer sirolimus-eluting coronary stent reduce medical costs and improve quality-adjusted life-years compared to a thin, durable-polymer everolimus-eluting stent?
The ultrathin, bioresorbable-polymer sirolimus-eluting stent provides modest cost savings and marginal QALY gains over 12 months compared to a durable-polymer everolimus-eluting stent, driven by lower peri-procedural myocardial infarction rates.
Answers are grounded in this paper and cite their sources.
May reduce periprocedural costs; leaves open whether differences justify preferential stent selection.
OBJECTIVES: The study estimated the health economic impact of a latest generation coronary stent with ultrathin struts and bioresorbable polymer coating. BACKGROUND: The recent BIOFLOW V trial, an international FDA approval trial (ClinicalTrials.gov: NCT02389946), has shown that an ultrathin, bioresorbable polymer sirolimus-eluting stent had a significantly lower rate of target lesion failure and target vessel-related myocardial infarction than a thin, durable polymer everolimus-eluting stent at 12 months, driven by a lower rate of peri-procedural myocardial infarction (ppMI). METHODS: We used a Markov model to project mortality and cost outcomes of that lower ppMI rate from a U.S. health system perspective over a 12-month horizon. Model parameters were derived from BIOFLOW V trial data, a systematic literature review and expert interviews. RESULTS: Use of the bioresorbable polymer sirolimus-eluting stent compared to durable polymer everolimus-eluting stent is associated with net reductions in medical cost of $124 (Interquartile Range (IQR) $97-154) per patient in 2018 US$, of which $115 (IQR $76-124) accrues to the initial admission and $10 (IQR $7-72) to cost of follow-up. The lower rate of ppMI translates into a gain of 0.000017 (IQR 0.000011-0.000022) quality-adjusted life-years (QALY) per patient. CONCLUSIONS: Lower ppMI rates of bioresorbable polymer sirolimus-eluting stent translate into reductions in direct medical cost, while improving patient outcomes. Most of the cost reduction is attributed to the initial admission with moderate savings up to 12 months post-discharge.
No takes yet. Share an insight, caveat, or question.
Mattke et al. (2018) studied this question. Ultrathin, bioresorbable-polymer sirolimus-eluting coronary stent vs. Thin, durable-polymer everolimus-eluting stent was evaluated on Medical cost and quality-adjusted life-years (QALY) (Net reduction of $124). Use of a bioresorbable-polymer sirolimus-eluting stent compared to a durable-polymer everolimus-eluting stent reduced medical costs by $124 per patient and gained 0.000017 QALYs over 12 months.
Synapse has enriched 10 related papers. Consider them for comparative context: