Key result
The common carotid artery exhibited higher mean wall shear stress and lower turbulence index compared to the subclavian and common femoral arteries in healthy adults.
Why the study?
To investigate the feasibility of the vector flow imaging technique for measuring peripheral arterial hemodynamic parameters in healthy adults and compare results across different arteries.
Does vector flow imaging (V Flow) detect differences in wall shear stress and turbulence index among normal common carotid, subclavian, and common femoral arteries in healthy adults?
Cross-Sectional (n=52)
No
Does vector flow imaging (V Flow) detect differences in wall shear stress and turbulence index among normal common carotid, subclavian, and common femoral arteries in healthy adults?
Vector flow imaging is a feasible quantitative approach for assessing wall shear stress and turbulence in peripheral arteries, revealing significant hemodynamic differences between carotid, subclavian, and femoral arteries in healthy adults.
Answers are grounded in this paper and cite their sources.
V Flow feasibly quantifies peripheral artery hemodynamics; leaves open its clinical utility pending prospective validation.
Objectives To investigate the feasibility of the vector flow imaging (V Flow) technique to measure peripheral arterial hemodynamic parameters, including wall shear stress (WSS) and turbulence index (Tur) in healthy adults, and compare the results in different arteries. Materials and methods Fifty-two healthy adult volunteers were recruited in this study. The maximum and mean values of WSS, and the Tur values at early-systole, mid-systole, late-systole, and early diastole for total 156 normal peripheral arteries [common carotid arteries (CCA), subclavian arteries (SCA), and common femoral arteries (CFA)] were assessed using the V Flow technique. Results The mean WSS values for CCA, SCA, and CFA were (1.66 ± 0.68) Pa, (0.62 ± 0.30) Pa, and (0.56 ± 0.27) Pa, respectively. The mean Tur values for CCA, SCA, and CFA were (0.46 ± 1.09%), (20.7 ± 9.06%), and (24.63 ± 17.66%), respectively. The CCA and SCA, as well as the CCA and CFA, showed statistically significant differences in the mean WSS and the mean Tur (P < 0.01). The mean Tur values had a negative correlation with the mean WSS; the correlation coefficient between log(Tur) and WSS is −0.69 (P < 0.05). Conclusion V Flow technique is a simple, practical, and feasible quantitative imaging approach for assessing WSS and Tur in peripheral arteries. It has the potential to be a useful tool for evaluating atherosclerotic plaques in peripheral arteries. The results provide a new quantitative foundation for future investigations into diverse arterial hemodynamic parameters.
No takes yet. Share an insight, caveat, or question.
Song et al. (2022) conducted a cross-sectional in Healthy adults (n=52). Peripheral artery location (Common Carotid Artery) vs. Subclavian and Common Femoral Arteries was evaluated on Mean wall shear stress (WSS) in Pa (p=<0.01). The common carotid artery exhibited higher mean wall shear stress and lower turbulence index compared to the subclavian and common femoral arteries in healthy adults.
Synapse has enriched 10 related papers. Consider them for comparative context: