Key result
Smartwatch-acquired electrocardiographs produced tracings of sufficient precision for interpretation across 12 studies, with 100% of patients able to use them accurately in 4 studies.
Why the study?
This review was conducted to summarise the literature on the ability of commercial smartwatches to produce diagnostic-quality electrocardiographs for interpreting Einthoven and precordial leads.
Do commercial smartwatches produce electrocardiographs of diagnostic quality for interpreting Einthoven and precordial leads?
Systematic Review
Do commercial smartwatches produce electrocardiographs of diagnostic quality for interpreting Einthoven and precordial leads?
Early evidence suggests that smartwatch-acquired electrocardiographs (specifically Apple Watch) produce diagnostic-quality tracings for Einthoven and precordial leads.
May support patient-performed multi-lead ECGs in practice; extends evidence beyond single-lead recordings.
Introduction This review aims to summarise the literature regarding the ability of commercial smartwatch products to produce an electrocardiograph of diagnostic quality for interpreting Einthoven and precordial leads. Methods PubMed, Embase, MEDLINE Complete, Web of Science, and Scopus were systematically searched. Articles were screened by a sole investigator against the inclusion criteria – first by title, then abstract, then full text. The reference lists of included articles were also screened. The inclusion criteria were: discussion of smartwatch-acquired tracing of Einthoven or precordial lead accuracy, and demonstrating sufficient rigor when undergoing critical appraisal using the Joanna Briggs Institute evaluation tools. A synopsis of results was provided in a summary of information table. Results Twelve articles were identified for inclusion, nine of which had physician (cardiology or emergency specialty) evaluation of tracings, one of which had statistical comparison of wave duration and amplitude, and two of which were expert commentary. Only evaluations of Apple Watch products were discovered during the literature search. All leads in all studies were considered suitable for interpretation, with no clinically significant differences. Four studies found that 100% of patients were able to accurately use a smartwatch as an electrocardiogram after a brief tutorial. Conclusion The current early evidence, based largely on visual evaluations by cardiologists during the previous year, suggests that electrocardiograph abnormality recorded by this technology is sufficiently precise to be presumed accurate until proven otherwise.
No takes yet. Share an insight, caveat, or question.
Matt Wilkinson-Stokes (2020) conducted a systematic review in Electrocardiograph interpretation. Smartwatch-acquired electrocardiographs (Apple Watch) was evaluated on Diagnostic quality for interpreting Einthoven and precordial leads. Smartwatch-acquired electrocardiographs produced tracings of sufficient precision for interpretation across 12 studies, with 100% of patients able to use them accurately in 4 studies.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: