The study questions the validity of APTT-based assays for identifying qualitative protein C abnormalities with defective interaction with protein S due to variable sensitivity of commercial reagents.
Answers are grounded in this paper and cite their sources.
APTT assays warrant caution for protein C-S defect detection due to reagent variability; leaves open validation of Xa-based methods.
In vivo expression of protein C activity is dependent on the availability of the activated protein C (APC) cofactor protein S. In the clinical laboratory, measurement of protein C anticoagulant activity is mostly performed in modified APTT assays. We have evaluated 13 commercial APTT reagents for their sensitivity to the cofactor effect of protein S by comparing APC-dependent clotting time prolongations in normal plasma and in protein S depleted plasma. In normal plasma, the sensitivities of the APTT reagents to the anticoagulant effect of APC were markedly different and correlated with the sensitivity of reagents to factor V and VIII. Reagents containing soy phosphatides appeared more sensitive than reagents containing phospholipid of animal origin. Analysis of dose-response curves obtained in normal plasma distinguished one group of reagents showing clotting time prolongations linearly related to the APC concentrations, a second group showing a log-linear relationship and a third group showing a log-log relationship. In protein S depleted plasma, sensitivity of APTT reagents to APC was in general proportional to that observed in normal plasma. However, for some reagents dose-response curves were qualitatively different in normal and in protein S depleted plasma. With all the APTT reagents, APC-dependent clotting time prolongations corresponding to 30-80% of APC anticoagulant activity observed in normal plasma, were observed in protein S depleted plasma. At variance, in a modified Xa one-stage clotting assay, negligible clotting time prolongations were observed in protein S depleted plasma, indicating that over 90% of the APC anticoagulant activity was protein S dependent in this assay system. Dilution of a relative insensitive APTT reagent effectively increased its sensitivity to the cofactor effect of protein S, suggesting that different phospholipid content and/or composition might be responsible for the different sensitivity of APTT reagents to protein S. These results question the validity of APTT based assays for the identification of qualitative protein C abnormalities with defective interaction with protein S.
No takes yet. Share an insight, caveat, or question.
D’Angelo et al. (1989) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: