Answers are grounded in this paper and cite their sources.
To find out how large the total diameter of an open-loop intraocular lens (IOL) should be, we studied 90 consecutive implantations of a one-piece poly(methyl methacrylate) IOL with a 7 mm biconvex optic and a total diameter of 10 mm (Adatomed 75 ST). The lens design made implantation simple, even through a small capsulorhexis. In 85% of the cases, the IOL remained well centered. One case with asymmetric placement of the IOL showed a decentration of more than 1 mm. In 14% of the eyes slight decentrations occurred because the capsular bag was too large. Contact between the iris and IOL was found in 15%. In 4% there were folds in the posterior capsule, and in 35% there was a small space between the IOL and the posterior capsule because the capsular bag was too large. Although the ST lens has a small total diameter, it remained at a distance from the iris in most cases. In-the-bag implantation through a continuous central capsulorhexis is mandatory to avoid secondary displacement; nevertheless, slight decentrations cannot be excluded. For a large capsular bag, the total diameter of an IOL should exceed 10 mm. Clinical results, cellular reaction on the lens surface (26.6%), biocompatibility, and visual performance are comparable to those of other well-approved poly(methyl methacrylate) IOLs.
No takes yet. Share an insight, caveat, or question.
Amon et al. (1993) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: