The hemagglutination-inhibition test and microneutralization test perform similarly for detecting high-titer antibodies to avian infectious bronchitis virus, but differ for low-titer sera.
Answers are grounded in this paper and cite their sources.
Either test may suit high-titer avian IBV serology; leaves open optimal choice for low-titer samples.
An evaluation was made of the hemagglutination-inhibition test and the constant-virus diluting-serum microneutralization test, two serological techniques that are used in detecting antibodies to avian infectious bronchitis. The repeatabilities and sensitivities of both tests were similar. Both tests compared favorably when testing high-titered antisera, but antibody titers detected varied when low-titered sera were used.
No takes yet. Share an insight, caveat, or question.
Hatcher et al. (1983) studied this question.